A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Endovascular Rescue Strategies for Nonopening of Pipeline Device: Report of Two Cases. | LitMetric

Endovascular Rescue Strategies for Nonopening of Pipeline Device: Report of Two Cases.

Asian J Neurosurg

Department of Neurosciences, Medanta-The Medicity, Gurgaon, Haryana, India.

Published: November 2019

We report two cases of rescue strategies for nonopening of Pipeline flow-diverter device for the treatment of intracranial aneurysm. The first patient, a 65-year-old female, presented with complaints of headache for 3 months and was found to have giant supraclinoid internal carotid artery (ICA) (ophthalmic segment) aneurysm. We planned endovascular partial coiling and flow-diverter placement for the treatment of ICA aneurysm. During the progressive deployment of PED, there was nonopening of Pipeline embolization device (PED) at its proximal end. We tried multiple attempts to navigate Marksman microcatheter over the PED delivery microwire and Echelon microcatheter over the Traxcess microwire across the pinched site, but we were not able to achieve success. After that, we tried opposite transcranial approach across prominent anterior communicating artery with the Synchro and Transcend microguidewire which finally resulted in the opening of the device; however, there was acute extravasation of dye on check angiogram. Thus, our technical success turned into disaster. The second patient, a 55-year-old female, presented with complaint of seizures for 3 months due to mass effect of cavernous sinus aneurysm. Pipeline Flex flow-diverter placement was done across the aneurysm neck. During the progressive deployment of device, there was nonopening of the mid and proximal segment of Pipeline Flex which was successfully managed by intra-Navien deployment of device followed by simultaneous push of Marksman microcatheter and pull of Navien catheter. In our case series, two rescue strategies were applied to successfully open the proximal constricted portion of Pipeline Flex; however, technical success in one case resulted in unmanageable disasters. Thus, transcranial rescue strategy for opening the constricted Pipeline Flex device should be cautiously used in our endovascular practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6896616PMC
http://dx.doi.org/10.4103/ajns.AJNS_191_19DOI Listing

Publication Analysis

Top Keywords

pipeline flex
16
rescue strategies
12
nonopening pipeline
12
strategies nonopening
8
report cases
8
female presented
8
flow-diverter placement
8
progressive deployment
8
marksman microcatheter
8
technical success
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!