Background: Bypassing the emergency department and the computed tomography suite by directly transporting to the neuroangiography suite for imaging assessment and treatment may shorten reperfusion times while maintaining proper patient selection.
Objective: To determine whether flat-panel detector multiphase computed tomography angiography protocol is associated with reduced treatment times and a similar safety profile as the standard imaging protocol.
Methods: Single-center prospective study of consecutive patients with anterior circulation large vessel occlusion strokes transferred to our facility for consideration of endovascular therapy from May 2016 to December 2017. Those with basilar strokes and/or presenting to the emergency department were excluded. Patients were categorized into two groups: (1) flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment group, with patients transferred directly to the suite for multiphase computed tomography angiography; and (2) patients undergoing standard protocol including computed tomography ± computed tomography angiography/CT perfusion. The groups were matched for age, baseline National Institute of Health Stroke Scale, and pretreatment glucose. Baseline characteristics, time metrics, and outcomes were compared.
Results: Out of 419 patients who underwent endovascular therapy over the study period, 210 patients fit inclusion criteria, with 54 (25.7%) in the flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment group. After matching, 49 flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment/control pairs were generated and analyzed. Baseline characteristics were well balanced. Flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment patients had significantly shorter median door-to-puncture (33 [26.5-47] vs. 55 [44.5-66] min, < 0.001), door-to-reperfusion (85 [57.5-115.5] vs. 110 [80-153], = 0.005) and picture-to-puncture (18 [13.5-22.5] vs. 42 [32-47.5] min, < 0.001) times. There were no differences in rates of successful reperfusion (modified thrombolysis in cerebral infarction 2b-3, 95.9% vs. 100%, = 0.5), parenchymal hematomas type-2 (4.1% vs. 2%, = 1.00), good outcome (90-day modified Rankin Scale 0-2, 44.9% vs. 40.8%, = 0.68), and 90-day mortality (14.3% vs. 22.4%, = 0.30).
Conclusion: Directly transferring patients to angiography and using multiphase computed tomography angiography to determine the eligibility for endovascular therapy is safe and may result in a significant reduction in treatment times. Future larger studies are warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1747493019895655 | DOI Listing |
Tuberk Toraks
December 2024
Department of Neurosurgery, Yale University Faculty of Medicine, New Haven, United States.
Introduction: This study aimed to evaluate the imaging findings of the chest flat panel detector computed tomography (FDCT) among coronavirus disease-2019 (COVID-19) positive patients during urgent/emergent interventional neuroradiologic procedures.
Materials And Methods: Chest FDCT examinations were performed using a C-arm mounted FDCT within the interventional radiology (IR) suite if the reverse transcription polymerase chain reaction (RT-PCR) results were pending in patients with clinical findings suggestive of COVID-19. In those who already had positive RT-PCR results, FDCT was performed for acute evaluation only if an acute unexpected cardiopulmonary event occurred during the procedure.
Injury
December 2024
Department of Orthopaedics, Larnaca General Hospital, State Health Services Organisation, Larnaca, Cyprus.
The purpose of this study was to establish typical dose values at orthopaedic operating rooms of the Larnaca General Hospital (LGH). Kerma area product (KAP), fluoroscopy time (FT) and cumulative air-kerma (K) measurements were collected for 821 patients who underwent common and reproducible trauma surgery over a five-year period, with three mobile C-arm systems; two equipped with an image-intensifier and one with a flat-panel detector. Dose indices were automatically extracted from radiation dose structured reports or DICOM meta-data files archived in the PACS, using custom-made software.
View Article and Find Full Text PDFEur J Radiol
December 2024
The Health Information and Quality Authority (HIQA), Unit 1301, City Gate, Mahon, Cork, T12 Y2xt Cork, Ireland. Electronic address:
Purpose: The purpose of this work was to establish national Irish diagnostic reference levels (DRLs) for a clinically representative and comprehensive list of clinical indications, anatomical regions, and common procedures for fluoroscopy and fluoroscopically guided interventions and compare these, where possible, to other DRLs established at a national level.
Method: A list of clinical indications, anatomical regions and common procedures was established. A national database of service providers was used to identify all medical radiological facilities providing fluoroscopy and fluoroscopically guided intervention services.
Ont Health Technol Assess Ser
December 2024
Background: In medicine, x-rays are used to generate images of tissues and structures inside the body. X-rays are emitted by a source device and, after passing through the body, strike a detector, which forms an image of the tissues and structures the x-rays passed through. Dual-energy subtraction (DES) x-ray systems use radiation of different energy spectra (energy levels) and the principle of differential absorption characteristics of bone and soft tissue to produce separate bone and soft tissue x-ray images, in addition to a conventional x-ray image.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
State Key Laboratory of Solidification Processing, Key Laboratory of Radiation Detection Materials and Devices, and School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
Inorganic halide perovskite thin-film X-ray detectors have attracted great research interest in recent years due to their high sensitivity, low detection limit, and facile fabrication process. The poor crystal quality of the thin film with uncontrollable thickness and low background voltage during detection limits its practical application. Here, a high-quality CsPbBrI ( = 0, 1) columnar crystal film is prepared by an improved melt-confined method with a porous anodic aluminum oxide (AAO) template, which stabilizes the disorder perovskite systems of CsPbBrI by stress.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!