Purpose: To evaluate the effectiveness and safety of a new trifocal intraocular lens (IOL) after cataract removal in patients living in Japan.

Study Design: Prospective multicenter clinical study.

Methods: One hundred and thirty-five eyes of 68 patients (19 men, 49 women; mean age, 66.3 ± 7.4 years) were followed for 6 months. Trifocal IOLs with focal points at near, intermediate, and distance were implanted bilaterally in eyes with less than 1 diopter of corneal astigmatism. The visual acuity (VA) at distance, 60 and 40 centimeters (cm), and contrast sensitivities were measured. Patients completed quality-of-life questionnaires preoperatively and postoperatively.

Results: The mean bilateral logarithm of the minimum angle of resolution VA at 5 meters (m), 60 cm, and 40 cm were, respectively: uncorrected, - 0.104 ± 0.095, - 0.065 ± 0.111, and - 0.042 ± 0.105; and distance-corrected, - 0.197 ± 0.076, - 0.112 ± 0.111, and - 0.073 ± 0.111. The contrast sensitivities at distance and near were within the normal range at all spatial frequencies under photopic conditions. Patients reported complete spectacle independence in 75.0% of cases. Total use of spectacles was reported by 1.5% and partial by 20.6%; the purpose of spectacle use was primarily for near visual tasks. Mild-to-moderate glare was reported by 65.7% of patients and halos by 70.1%; only 1.5% of subjects reported severe glare and halos.

Conclusions: This new trifocal IOL provides equally good uncorrected VAs at distance, intermediate, and near, and decreases spectacle dependence in daily life. Patients frequently report mild-to-moderate glare and halos, and patients should be informed about these before implantation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10384-019-00712-4DOI Listing

Publication Analysis

Top Keywords

trifocal intraocular
8
intraocular lens
8
contrast sensitivities
8
mild-to-moderate glare
8
patients
7
clinical evaluation
4
trifocal
4
evaluation trifocal
4
lens japan
4
japan purpose
4

Similar Publications

Purpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.

Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively.

View Article and Find Full Text PDF

An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, "advanced technology" IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.

View Article and Find Full Text PDF

Impact of central corneal astigmatism on postoperative visual outcomes in patients undergoing trifocal intraocular lens implantation.

BMC Ophthalmol

January 2025

Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.

Background: To investigate the impact of central corneal astigmatism on postoperative visual outcomes in patients with trifocal intraocular lens (IOL) implantation.

Methods: This retrospective study included 278 eyes of 278 patients who underwent uneventful cataract surgery with implantation of the trifocal IOL (AT LISA tri 839MP). Patients were divided into two groups according to the total corneal refractive power (TCRP) in 3 mm zone centered on the corneal apex: low astigmatism group, TCRP ≤ 0.

View Article and Find Full Text PDF

A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.

J Clin Med

December 2024

The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.

This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.

View Article and Find Full Text PDF

Purpose: To observe and explore the correlation between visual outcomes and intraocular lens (IOL) stability after tri-focal IOL implantation in eyes with high myopia.

Methods: Patients with highly myopic cataract (axial length > 26 mm) were enrolled in this prospective study. Thirty-one eyes (31 patients) received implantation of a trifocal IOL (AcrySof IQ PanOptix TFNT00).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!