Minimum toe clearance (MTC ∼10-30 mm) is a hazardous mid-swing gait event, characterized by high-foot velocity (∼4.60 m·s-1) and single-foot support. This experiment tested treadmill-based gait training effects on MTC. Participants were 10 young (4 males and 6 females) and 10 older (6 males and 4 females) healthy ambulant individuals. The mean age, stature, and body mass for the younger group was 23 (2) years, 1.72 (0.10) m, and 67.5 (8.3) kg, and for older adults was 77 (9) years, 1.64 (0.10) m, and 71.1 (12.2) kg. Ten minutes of preferred speed treadmill walking (baseline) was followed by 20 minutes with MTC information (feedback) and 10 minutes without feedback (retention). There were no aging effects on MTC in baseline or feedback. The MTC in baseline for older adults was 14.2 (3.5) mm and feedback 27.5 (8.7) mm, and for the younger group, baseline was 12.7 (2.6) mm and feedback 28.8 (5.1) mm, respectively. Retention MTC was significantly higher for both groups, indicating a positive effect of augmented information: younger 40.8 (7.3) mm and older 27.7 (13.6) mm. Retention joint angles relative to baseline indicated that the young modulated joint angles control MTC differently using increased ankle dorsiflexion at toe off and modulating knee and hip angles later in swing closer to MTC.

Download full-text PDF

Source
http://dx.doi.org/10.1123/jab.2018-0291DOI Listing

Publication Analysis

Top Keywords

gait training
8
mtc
8
effects mtc
8
males females
8
younger group
8
older adults
8
mtc baseline
8
joint angles
8
baseline
5
feedback
5

Similar Publications

Objective: This multicenter, randomized, double-blind, placebo-controlled, crossover trial aimed to evaluate whether prolonged noisy galvanic vestibular stimulation improves body balance in patients with vestibulopathy.

Materials And Methods: This trial was registered in the Japan Pharmaceutical Information Center Clinical Trials Information registry (jRCT1080224083). Subjects were 20- to 85-year-old patients who had been unsteady for more than one year and whose symptoms had persisted despite more than six months of rehabilitation.

View Article and Find Full Text PDF

To reduce hip joint muscles' activation during walking with an active hip exoskeleton. Few studies examine the optimal active assistance timing of the hip exoskeleton based on muscle activation characteristics. Sixteen gender-balanced healthy adults (mean age 28.

View Article and Find Full Text PDF

Human-Inspired Gait and Jumping Motion Generation for Bipedal Robots Using Model Predictive Control.

Biomimetics (Basel)

January 2025

Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu-ku, Kitakyushu 808-0135, Japan.

In recent years, humanoid robot technology has been developing rapidly due to the need for robots to collaborate with humans or replace them in various tasks, requiring them to operate in complex human environments and placing high demands on their mobility. Developing humanoid robots with human-like walking and hopping abilities has become a key research focus, as these capabilities enable robots to move and perform tasks more efficiently in diverse and unpredictable environments, with significant applications in daily life, industrial operations, and disaster rescue. Currently, methods based on hybrid zero dynamics and reinforcement learning have been employed to enhance the walking and hopping capabilities of humanoid robots; however, model predictive control (MPC) presents two significant advantages: it can adapt to more complex task requirements and environmental conditions, and it allows for various walking and hopping patterns without extensive training and redesign.

View Article and Find Full Text PDF

Parkinson's disease is the second most common neurodegenerative disease worldwide, characterized by bradykinesia, rigidity, tremor, and postural instability. These symptoms often lead to significant postural deformities and an increased risk of falls, severely impacting the quality of life. Conventional rehabilitation methods have shown benefits, but recent advancements suggest that virtual reality (VR) could offer a promising alternative.

View Article and Find Full Text PDF

Exoskeleton Robot Training in Two Patients with an Electrical Burn and Septic Arthritis: A Case Report.

J Burn Care Res

January 2025

Department of Rehabilitation Medicine, Hangang Sacred Heart Hospital, College of Medicine, Hallym University, Seoul, Korea.

Septic arthritis (SA) are rare in patients with burns, but delayed treatment can result in irreversible joint destruction. Early diagnosis and immediate treatment are necessary to prevent joint destruction. Robot training in patients with musculoskeletal diseases and burns, can improve joint range of motion (ROM), muscle strength, and lower extremity function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!