Purpose: The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading.

Materials And Methods: The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (10 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces.

Results: There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant.

Conclusion: The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6933047PMC
http://dx.doi.org/10.4047/jap.2019.11.6.305DOI Listing

Publication Analysis

Top Keywords

axial displacement
24
tensile removal
24
cyclic loading
20
removal force
20
cad/cam abutments
16
cad/cam abutment
12
prefabricated abutment
12
removal torque
12
prefabricated abutments
12
removal
9

Similar Publications

Aims: Aortic wall stiffening in ascending thoracic aortic aneurysm (aTAA) is common. However, the spatial and temporal relationships between stiffness, aortic size, and growth in aTAA remain unclear.

Methods And Results: In this single-centre retrospective study, we utilized vascular deformation mapping to extract multi-directional aortic motion, aortic distensibility, and aortic growth in a multi-planar fashion from multi-phasic ECG-gated computed tomography angiograms.

View Article and Find Full Text PDF

Introduction: Neuroblastoma is an embryonic tumor of the peripheral sympathetic nervous system. It is the most common extracranial solid tumor of childhood and accounts for up to 15% of all pediatric cancer fatalities. The manifestation of neuroblastoma is variable depending on the location of the tumor and the presence or absence of paraneoplastic syndromes.

View Article and Find Full Text PDF

In urban concentrated area, the disturbance caused by construction affects significantly the sustainability of adjacent existing structures. It is essential to capture the mechanical response of existing structures to adjacent deep excavation. The objective of this paper is to investigate the displacement and internal force behavior of elevated bridge piles (BP) subject to influence of deep excavation.

View Article and Find Full Text PDF

When underground tunnels in coal mines traverse geological structurally abnormal zones (faults, collapse columns, fractured zones, etc.), excavation-induced unloading leads to instability and failure of the engineering rock mass. Rock masses in fractured zones are in elastic, plastic, and post-peak stress states, and the process of excavation through these zones essentially involves unloading under full stress paths.

View Article and Find Full Text PDF

Through the ferrite single-phase parameters of M50 bearing steel obtained based on nanoindentation experiments and the representative volume element (RVE) model established based on the real microstructure of M50, this paper established a multiscale finite element model for the cold ring rolling of M50 and verified its accuracy. The macroscale and mesoscale flow behaviors of the ring during the cold rolling deformation process were examined and explained. The macroscopic flow behavior demonstrated that the stress distribution was uniform following rolling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!