Chromatographic media play a crucial role in the downstream processing of biotechnology products. The physical and chemical properties of these processing aids are mostly monitored by expensive and time-consuming preparative tests, but spectroscopic techniques may also be used to measure chromatographic media samples. In this study, chromatographic media formulations used in downstream processes were investigated using attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy. Samples were measured both in original suspension form and after drying to examine the possibilities of a potential spectroscopic method without sample preparation. Principal component analysis (PCA) was employed to identify the spectral differences among the formulations with distinct support matrices and functional groups and soft independent modeling of class analogy (SIMCA) was performed to creating classification models for identification of chromatography media. To increase the number of samples in the SIMCA, simulated spectra were generated based on the experimental spectra. PCA models indicated that spectra of samples in original suspension form and after drying contained similar information about the chemical properties of chromatographic media samples. Moreover, during the classification of spectra based on SIMCA, both measurement techniques gave high sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) results. These results show that ATR FT-IR could be applied as a simple alternative method for monitoring the chromatography media samples. This technique is also feasible without sample preparation. Thereby the multi-hours drying steps may be omitted, the measurements can be performed in a few minutes, and the potential effects of sample preparations can be eliminated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2019.113060 | DOI Listing |
Int J Mol Sci
December 2024
Department of Chemistry, College of Science, Taif University, Taif P.O. Box 11099, Saudi Arabia.
In this study, new monolithic poly(9-anthracenylmethyl methacrylate-co-trimethylolpropane trimethacrylate (TRIM) columns, referred as ANM monoliths were prepared, for the first time, and were used for the separation media for biomolecules and proteomics analysis by nano-liquid chromatography (nano-LC). Monolithic columns were prepared by in situ polymerization of 9-anthracenylmethyl methacrylate (ANM) and trimethylolpropane trimethacrylate (TRIM) in a fused silica capillary column of 100 µm ID. Polymerization solution was optimized in relation to monomer and porogenic solvent.
View Article and Find Full Text PDFACS ES T Eng
October 2024
School of Sustainable Engineering & the Built Environment, Arizona State University, Tempe, Arizona 85287, United States of America.
A one-pot, acid-, base-, and metal-free, multicomponent strategy has been developed to synthesize spiro thiochromene-oxindole derivatives as potential anti-inflammatory agents. The synthesized compounds were screened for their anti-inflammatory activity by inhibiting heat-induced Bovine Serum Albumin (BSA) denaturation assay, revealing moderate to good efficacy. Compounds 4e, 4k, and 4h exhibited the highest activity, inhibiting BSA denaturation by 90.
View Article and Find Full Text PDFJ Sep Sci
December 2024
College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming, China.
Chiral macrocycles have emerged as attractive media for chromatographic enantioseparation due to their excellent host-guest recognition properties. In this study, a new chiral stationary phase (CSP) based on 1,1'-binaphthyl chiral polyimine macrocycle (CPM) was reported. The CPM was synthesized by one-step aldehyde-amine condensation of (S)-2,2'-dihydroxy-[1,1'-binaphthalene]-3,3'-dicarboxaldehyde with 1,2-phenylenediamine and bonded on thiolated silica via the thiol-ene click reaction to afford the CSP.
View Article and Find Full Text PDFJ Pharm Sci
December 2024
Therapeutics Development & Supply, Janssen Research & Development, NV, a Johnson & Johnson company, Beerse, Belgium.
Small interfering RNAs (siRNAs) have emerged as a highly promising class of therapeutics, capable of effectively treating a wide range of indications, including previously challenging targets. To correctly characterize the duplex content of siRNA therapeutics, a careful design of the analytical conditions is required. This is due to the weak interactions governing the duplex formation and thermal stability of these double-stranded oligonucleotides.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!