Background: The amalgamation method used by artisanal small-scale miners is the single largest source of global mercury emission. The goal of the 'Free Your Mine' project is to stop mercury use in artisanal and small-scale mining.

Objectives: The aim of the present study was to compare gold recovery and time consumption between the amalgamation method and direct smelting, using borax for smelting under standardized conditions.

Materials And Methods: This was an experimental study in a pragmatic setting in the mining community of Tiira, Uganda. Standardized amounts of gold ore of equal quality were processed with the local amalgamation method and with the Philippine mercury-free method as practiced by miners from Benguet in the Philippines, and the gold yield and time consumption were compared.

Results: The amalgamation method took 53 minutes and recovered 1.0 g of pure gold. The miners used 4 g of mercury in the processing. The Philippine mercury-free method took 62 minutes and recovered 1.4 g of pure gold.

Conclusions: The Philippine mercury-free method recovered 40% more gold than the amalgamation method but took 9 minutes longer. The Philippine mercury-free method is a viable alternative to amalgamation.

Competing Interests: The authors declare no competing financial interests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6905143PMC
http://dx.doi.org/10.5696/2156-9614-9.24.191205DOI Listing

Publication Analysis

Top Keywords

amalgamation method
20
philippine mercury-free
16
mercury-free method
16
artisanal small-scale
12
method minutes
12
method
9
gold yield
8
direct smelting
8
time consumption
8
minutes recovered
8

Similar Publications

Halitosis presents a significant global health concern, necessitating the development of precise and efficient testing methodologies owing to the high prevalence and the associated social and psychological effects. The measurement of volatile sulfur compounds (VSCs), recognized as primary contributors to halitosis, is particularly significant. While gas chromatography (GC-MS) offers accurate measurements, its bulky and expensive nature limits widespread accessibility.

View Article and Find Full Text PDF

Background: The prevalence of dementia in Peru's northern regions is poorly documented, largely due to the scarcity of studies employing validated assessment tools for the elderly. Notably, this area is marked by pronounced disparities, encompassing a wide range of socioeconomic statuses and predominantly low educational attainment. The confluence of risk factors, including educational and socioeconomic deprivation, prevalent diseases, suboptimal health conditions, chronic stress, and lifelong malnutrition, poses a significant risk of escalating dementia cases over the next two decades.

View Article and Find Full Text PDF

Innovative breast cancer detection using a segmentation-guided ensemble classification framework.

Biomed Eng Lett

January 2025

Electronics and Communication Engineering, IFET College of Engineering, Villupuram, Tamilnadu India.

Unlabelled: Breast cancer (BC) remains a significant global health issue, necessitating innovative methodologies to improve early detection and diagnosis. Despite the existence of intelligent deep learning models, their efficacy is often limited due to the oversight of small-sized masses, leading to false positive and false negative outcomes. This research introduces a novel segmentation-guided classification model developed to increase BC detection accuracy.

View Article and Find Full Text PDF

Cytosine-rich and poly(adenine)-tailed tetrahedral DNA framework (TDF) is designed as template (A-TDF) for anchoring silver nanoclusters (AgNCs) and igniting the dual-color fluorescence of AgNCs. The resultant DNA-AgNCs simultaneously emits red and green fluorescence, and the quantum yield of red fluorescence is as high as 44.8%.

View Article and Find Full Text PDF

Clinical Pharmacokinetics of Fexofenadine: A Systematic Review.

Pharmaceutics

December 2024

Department of Pharmacy Practice, Faculty of Pharmacy, Bahauddin Zakariya University, Multan 60800, Pakistan.

Fexofenadine hydrochloride is a widely prescribed drug for treating histamine-mediated allergic reactions. This review systematically collates existing research on the clinical pharmacokinetics (PK) of fexofenadine, with a copious emphasis on examining the impact of stereoisomerism, disease states, and drug interactions. The search engines PubMed, Science Direct, Google Scholar, and Cochrane were scanned systematically for articles concerning the clinical PK of fexofenadine in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!