AI Article Synopsis

  • The study reports on a new rotatable tabletop designed for Volumetric Modulated Arc Therapy (VMAT) in total-body irradiation (TBI), aimed at improving treatment efficiency.
  • Patients taller than 120 cm typically require position changes during treatment, but the tabletop allows for a quick 180° turn from head-first to feet-first without repositioning.
  • Initial results show that the tabletop significantly reduced treatment times, with an average of 57 minutes for the first fraction lowering to 38 minutes for the second, demonstrating its effectiveness in clinical practice.

Article Abstract

Background: Volumetric Modulated Arc Therapy (VMAT) techniques have recently been implemented in clinical practice for total-body irradiation (TBI). To date, most techniques still use special couches, translational tables, or other self-made immobilization devices for dose delivery. Aim of the present study was to report the first results of a newly developed rotatable tabletop designed for VMAT-TBI.

Methods: The VMAT-TBI technique theoretically allows the use of any standard positioning device at the linear accelerator. Nevertheless, the main problem is that patients taller than 120 cm cannot be treated in one position due to the limited cranial-caudal couch shift capacities of the linac. Therefore, patients are usually turned from a head-first supine position (HFS) to a feet-first supine position (FFS) to overcome this limitation. The newly developed rotatable tabletop consists completely of carbon fiber, including the ball bearing within the base plate of the rotation unit. The patient can be turned 180° from a HFS to a FFS position within a few seconds, without the need of repositioning.

Results: The first 20 patients had a median age of 47 years, and received TBI before bone marrow transplantation for acute myeloid leukemia. Most patients (13/20) received a TBI dose of 4 Gy in 2 fractions, twice daily. The mean number of applied monitor units (MU) was 6476 MU using a multi-arcs and multi-isocenter VMAT-TBI technique. The tabletop has been successfully used in daily clinical practice and helped to keep the treatment times at an acceptable level. During the first treatment fraction, the mean overall treatment time (OTT) was 57 min. Since no additional image guidance was used in fraction 2 of the same day, the OTT was reduced to mean 38 min.

Conclusions: The easy and reproducible rotation of the patient on the treatment couch using the rotatable tabletop, is time-efficient and overcomes the need of repositioning the patient after turning from a HFS to a FFS position during VMAT TBI. Furthermore, it prevents couch-gantry collisions, incorrect isocenter shifts and beam mix-up due to predicted absolute table coordinates, which are recorded to the R + V system with the corresponding beams.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6937701PMC
http://dx.doi.org/10.1186/s13014-019-1445-3DOI Listing

Publication Analysis

Top Keywords

rotatable tabletop
16
total-body irradiation
8
clinical practice
8
newly developed
8
developed rotatable
8
vmat-tbi technique
8
supine position
8
hfs ffs
8
ffs position
8
received tbi
8

Similar Publications

Novel rotatable tabletop for total-body irradiation using a linac-based VMAT technique.

Radiat Oncol

December 2019

Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.

Article Synopsis
  • The study reports on a new rotatable tabletop designed for Volumetric Modulated Arc Therapy (VMAT) in total-body irradiation (TBI), aimed at improving treatment efficiency.
  • Patients taller than 120 cm typically require position changes during treatment, but the tabletop allows for a quick 180° turn from head-first to feet-first without repositioning.
  • Initial results show that the tabletop significantly reduced treatment times, with an average of 57 minutes for the first fraction lowering to 38 minutes for the second, demonstrating its effectiveness in clinical practice.
View Article and Find Full Text PDF

Studies of bimolecular reaction dynamics using pulsed high-intensity vacuum-ultraviolet lasers for photoionization detection.

Phys Chem Chem Phys

September 2013

Department of Chemistry and Chemical Biology, Baker Laboratory, Cornell University, Ithaca, NY 14853-1301, USA.

This article describes recent progress on the development and application of pulsed high-intensity (~0.1 mJ per pulse) vacuum-ultraviolet (VUV) radiation produced by commercial tabletop lasers for studies of gas phase chemical reaction dynamics involving polyatomic free radicals. Our approach employs near-triply resonant four-wave mixing of unfocussed nanosecond dye lasers in an atomic gas as an alternative to the use of synchrotron light sources for sensitive universal soft photoionization detection of reaction products using a rotatable source crossed molecular beams apparatus with fixed detector.

View Article and Find Full Text PDF

With the development of intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (IMAT), volumetric single arc therapy (RapidArc) and cone beam CT (CBCT) in 3D conformal radiotherapy, a need for new homogeneous treatment tabletops has evolved. Therefore, a new homogenous carbon fibre rotatable treatment tabletop Contesse has been developed. The intension was to create a CT compatible treatment tabletop accommodating all the standard treatment areas without add-on devises or the need to reconfigure the tabletop in everyday practice.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!