The development of a novel patient-derived recovery scale for open tibial fractures.

Bone Joint J

Abertawe Bro Morgannwg University Health Board, Morriston Hospital, Swansea, UK.

Published: January 2020

Aims: The aim of this study was to develop a psychometrically sound measure of recovery for use in patients who have suffered an open tibial fracture.

Methods: An initial pool of 109 items was generated from previous qualitative data relating to recovery following an open tibial fracture. These items were field tested in a cohort of patients recovering from an open tibial fracture. They were asked to comment on the content of the items and structure of the scale. Reduction in the number of items led to a refined scale tested in a larger cohort of patients. Principal components analysis permitted further reduction and the development of a definitive scale. Internal consistency, test-retest reliability, and responsiveness were assessed for the retained items.

Results: The initial scale was completed by 35 patients who were recovering from an open tibial fracture. Subjective and objective analysis permitted removal of poorly performing items and the addition of items suggested by patients. The refined scale consisted of 50 Likert scaled items and eight additional items. It was completed on 228 occasions by a different cohort of 204 patients with an open tibial fracture recruited from several UK orthoplastic tertiary referral centres. There were eight underlying components with tangible real-life meaning, which were retained as sub-scales represented by ten Likert scaled and eight non-Likert items. Internal consistency and test-retest reliability were good to excellent.

Conclusion: The Wales Lower Limb Trauma Recovery (WaLLTR) Scale is the first tool to be developed from patient data with the potential to assess recovery following an open tibial fracture. Cite this article: 2020;102-B(1):17-25.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.102B1.BJJ-2019-0303.R2DOI Listing

Publication Analysis

Top Keywords

open tibial
28
tibial fracture
20
items
9
recovery open
8
cohort patients
8
patients recovering
8
recovering open
8
refined scale
8
analysis permitted
8
internal consistency
8

Similar Publications

Background: Distal tibial deformities are not assessed using the proximal anatomical axis (PAA) to determine the posterior tibial slope (PTS). Therefore, it seems advantageous to measure PTS on full-length lateral tibial radiographs using the mechanical axis (MA).

Purposes: To (1) compare the PTS measurements using the MA and the PAA and (2) determine whether using the PAA fails to detect a certain number of significantly elevated PTS values compared with using the MA.

View Article and Find Full Text PDF

Background: Consequences of osteochondral fractures associated with patellar dislocation can be severe for younger patients. Precise 3-dimensional characterization of fracture location, size, frequency, and radiographic associations remain undefined in this population.

Purpose: (1) To define the topographic characteristics of osteochondral fractures in pediatric and adolescent patients with first-time patellar dislocations and (2) to determine the relationship between these characteristics and radiographic and patient factors.

View Article and Find Full Text PDF

Background: A larger joint line convergence angle (JLCA) increases the stress load on the medial compartment. Few reports, however, have discussed the effect of the JLCA on the cartilage status and clinical outcomes after opening-wedge high tibial osteotomy (OWHTO).

Purpose/hypothesis: To reveal the effect of the JLCA on clinical results after OWHTO.

View Article and Find Full Text PDF

Aims: Open fractures of the tibia are associated with significant complications, for which attempts have been made to standardise and optimise their management. In the UK, this standard is the British Orthopaedic Association Standards for Trauma (BOAST) guidelines. The Scottish Open Fracture of Tibia (SOFT) Audit is a national review of open tibial shaft fractures across all four Scottish Trauma Networks, which aims to provide a definite review of ortho-plastic care for open tibial shaft fractures in Scotland.

View Article and Find Full Text PDF

Serious lower limb injuries following car gearbox explosion: A rare case report.

Trauma Case Rep

February 2025

Department of Surgery, Trauma & Vascular Surgery, Clinical Research, Hamad Medical Corporation, Doha, Qatar.

Car Gearbox explosion-related injuries are very rare but could be serious. We reported a 43-year-old female patient who sustained severe bilateral lower limb injuries following an explosion of the gearbox in her private car while waiting at a traffic signal. The patient suffered from a left open tibia shaft fracture and severely macerated soft tissues, along with an open wound on the right leg.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?