AI Article Synopsis

  • Intraoperative 3D navigation (ION) improves accuracy in spinal surgery but faces workflow challenges, particularly in adolescent idiopathic scoliosis (AIS) cases.
  • The study evaluated the implementation of ION using lean principles to enhance efficiency and safety during AIS surgery in 20 patients.
  • Key findings showed reduced operating time and radiation exposure, primarily by minimizing repeat scans, suggesting that lean techniques can successfully integrate ION into surgical practices for better outcomes.

Article Abstract

Aims: Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery.

Methods: A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed.

Results: The greatest gains in productivity were in avoiding repeat intraoperative scans (a mean of 248 minutes for patients who had two scans, and a mean 180 minutes for those who had a single scan). Optimizing accuracy was the biggest factor influencing this, which was reliant on incremental changes to the operating setup and technique.

Conclusion: The application of lean principles to the introduction of ION for AIS surgery helps assimilate this method into the environment of the operating theatre. Data and stakeholder analysis identified a reproducible technique for using ION for AIS surgery, reducing operating time, and radiation exposure. Cite this article: 2020;102-B(1):5-10.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.102B1.BJJ-2019-1054.R1DOI Listing

Publication Analysis

Top Keywords

lean principles
16
ais surgery
12
intraoperative navigation
8
spinal surgery
8
application lean
8
operating time
8
radiation exposure
8
ion ais
8
ion
7
surgery
6

Similar Publications

[F]FDG PET/CT for predicting neoadjuvant PD-L1 blockade monotherapy treatment response in patients with locally advanced esophageal squamous cell carcinoma: a preliminary study.

Eur J Nucl Med Mol Imaging

January 2025

Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, P.R. China.

Purpose: To investigate the predictive value of 2-[18F]-fluoro-2-deoxy-D-glucose ([F]FDG) PET/CT for evaluating primary tumor (PT) and lymph node (LN) responses after neoadjuvant programmed death-ligand 1 (PD-L1) blockade monotherapy in patients with locally advanced esophageal squamous cell carcinoma (LA-ESCC).

Methods: In the single-arm phase 1b NATION-1907 trial (NCT04215471), 23 patients with LA-ESCC received two cycles of neoadjuvant PD-L1 blockade Adebrelimab followed by surgery. Among these, 18 patients underwent [F]FDG PET/CT scans both before immunotherapy and prior to surgery.

View Article and Find Full Text PDF

Background: The study evaluated the relationship between balance function and skeletal muscle mass index (ASMI), physical function, and fatigue in children with chronic kidney disease (CKD).

Methods: A cross-sectional study of 83 children with CKD (stages 1-4, dialysis, transplant) and 71 healthy controls was conducted. Functional performance tests, including gait speed, 6-min walk distance (6MWD), five-repetition sit-to-stand (5RST), and timed up-and-go (TUG) tests, were administered.

View Article and Find Full Text PDF

Background: Many hospitals and surgery centers have focused improvement efforts on operating room inefficiencies. A common inefficiency is missing and unusable surgical instrumentation, which can result in case delays and decreased effectiveness. Lean Six Sigma methodology, a set of process improvement tools focused on the reduction of waste and variation, has been used to identify and correct root causes of missing and unusable instrumentation.

View Article and Find Full Text PDF

Purpose: This study intends to reveal the existing research stream and predict future research avenues for lean healthcare (LH). This paper analyzes the progress of LH research and identifies key trends, research gaps and future directions. By mapping the knowledge structure, the study offers insights into the effects of LH on healthcare efficiency, patient care and organizational performance.

View Article and Find Full Text PDF

Background: Research documents that drinking to cope behavior can be disrupted by enhancing emotion regulation and coping skills related to the experience of stress and negative affect. The Alpha Element Self-Coaching Plan incorporates principles of positive psychology and cognitive behavioral therapy to redirect negative thinking and emotions and, therefore, has the potential to benefit individuals who use alcohol to cope with stress.

Objective: This study aimed to evaluate satisfaction and usability of the online Alpha Element Self-Coaching Plan in order to inform the development of an expanded digital platform based on the Alpha Element framework.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!