Purpose: To determine the feasibility of performing intraocular surgeries in a heads-up position with low illuminance conditions by observing a display of the surgical field created by a three-dimensional imaging (3D) system.

Methods: Seventy-four eyes of 56 patients underwent cataract surgery (72 eyes) with the heads-up 3D surgery system; 60 eyes with cataract surgery alone, 7 eyes with combined cataract and glaucoma microdevice implant surgery, 5 eyes with combined cataract and vitrectomy surgery, and two eyes with vitrectomy surgery alone were studied. The illuminance from the surgical microscope was set to be dimmer (Leica M822F40 main light 2%; otto-flex 6%) than the usual setting to minimize the discomfort and glare for the patient. The surgeries were performed under topical anesthesia. The luminance of the images observed through the eyepieces of the operating microscope and the image of a 3D system created by a high-sensitivity sensor Exmor R 3CMOS HD camera (Sony MCC-1000MD) were measured.

Results: All surgeries were completed without any complications under the low illumination conditions. The surgical field on the display monitor was created by a 3D system using a high-sensitivity sensor camera and was observed in a heads-up position. The patients did not report any intolerable discomfort or glare during the surgery. Cataract surgeries were performed with a good view of the surgical field under the extremely low illumination from the surgical microscope. The high-sensitivity sensors and electronic amplifications of the image signals made the surgical field brighter and allowed the surgeon to perform the surgery confidently and safely.

Conclusions: Heads-up, 3D-assisted intraocular surgeries can be performed safely and efficiently with low illuminance of the surgical field. This trial is registered with UMIN000037838.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6899266PMC
http://dx.doi.org/10.1155/2019/5013463DOI Listing

Publication Analysis

Top Keywords

surgical field
20
surgery eyes
16
surgeries performed
12
heads-up surgery
8
intraocular surgeries
8
heads-up position
8
low illuminance
8
surgery
8
cataract surgery
8
eyes combined
8

Similar Publications

A co-registration method to validate optical coherence tomography in the breast surgical cavity.

Heliyon

January 2025

BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Australia.

Breast-conserving surgery accompanied by adjuvant radiotherapy is the standard of care for patients with early-stage breast cancer. However, re-excision is reported in 20-30 % of cases, largely because of close or involved tumor margins in the specimen. Several intraoperative tumor margin assessment techniques have been proposed to overcome this issue, however, none have been widely adopted.

View Article and Find Full Text PDF

Oral and maxillofacial surgery (OMS) is a field that straddles knowledge and clinical experience from both medical and dental specialties. In the small island nation of Singapore, the rapidly and constantly changing needs of its diverse and aging population, as well as changes in the mindsets of both students and educators have led to many developments in the local OMS program. Tied to the only dental school in the country, the curriculum of the training program has kept up with the changes in the demographics and attitudes of the local patient pool, which comprises a multicultural population with both traditional and modern mindsets.

View Article and Find Full Text PDF

Background: In recent years, the increase of the post-transplantation diabetes mellitus (PTDM) after renal transplantation encourages people to do a lot of research on the disease. This paper conducted a bibliometric study on PTDM related literature to explore the risk factors of diabetes after kidney transplantation, as well as the current status, hotspots and development trends of PTDM research, so as to provide reference for researchers in related fields.

Methods: We searched the Web of Science Core Collection (WoSCC) database for PTDM literature from January 1, 1990, to August 20, 2023, and used VOSviewer, CiteSpace, and the R package 'bibliometrix' to do bibliometric analysis.

View Article and Find Full Text PDF

Background: Surgical interventions are inherently complex and designing and conducting surgical randomised controlled trials (RCTs) can be challenging. Trial design impacts the applicability of trial results to clinical practice. Given the recent growth in numbers of surgical RCTs, there is a need to better understand the validity and applicability of trials in this field.

View Article and Find Full Text PDF

In all fields anatomical dissection has improved results - en bloc resection of bladder tumors (ERBT) will make no exception.

World J Urol

January 2025

Department of Urology, Spital Thurgau AG, Kantonsspital Frauenfeld, Pfaffenholzstrasse 4, Frauenfeld, CH, 8501, Switzerland.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!