The temporal consistency of the fAPAR GEOV2 full time series (constituted by data derived from SPOT-VGT1/2 and PROBA-V) is analyzed against the single-sensor MODIS dataset, with a particular focus on the most recent fAPAR anomalies (-scores) produced from PROBA-V in the period 2014-2017. The intercomparison highlights a systematic overestimation of GEOV2 fAPAR -scores when compared to MODIS fAPAR, likely related to the observed positive bias (over 90% of the domain) in the PROBA-V SPOT-VGT1/2 relationship. A simple two-step harmonization procedure has been proposed to remove this discrepancy, based on two separate linear corrections of SPOT-VGT1/2 (2001-2013) and PROBA-V (2014-2017) data with respect to MODIS, followed by a time lag correction. The harmonized GEOV2 time series preserves the overall dynamic of fAPAR, while removing the sensor bias and improving the consistency with MODIS data. The fAPAR anomalies from the harmonized GEOV2 time series provide unbiased estimates of -scores that are overall well correlated ( = 0.55 ± 0.25) with the MODIS fAPAR anomalies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6919224 | PMC |
http://dx.doi.org/10.1016/j.jag.2019.03.017 | DOI Listing |
J Vasc Access
January 2025
Department of Nasopharyngeal Carcinoma, Sun Yat-sen University Cancer Center, Guangzhou, P.R. China.
Background: Central venous access devices (CVAD) are widely used in patient care, providing an essential, reliable pathway for patients to receive chemotherapy, long-term infusions, and nutritional support. However, a system of exercise management has not been developed in patients with CVAD.
Purpose: To evaluate and summarize the evidence for management exercise in patients with CVAD and provide guidance for clinical practice.
J Cardiovasc Surg (Torino)
February 2025
Department of Vascular Surgery, AZ Sint Blasius, Dendermonde, Belgium.
Background: Due to the heterogeneity of literature findings, stent type selection for the endovascular treatment of complex aorto-iliac occlusive disease remains challenging. The BELSTREAM study, a physician-initiated, prospective, multicenter, single-arm study, aims to report the safety and efficacy of the balloon expandable LifeStream Peripheral Stent Graft System (BD, Tempe, Arizona, USA) for the treatment of complex TASC C and D aorto-iliac artery lesions.
Methods: Seventy patients and 133 lesions were included at six Belgian institutions.
J Cardiovasc Surg (Torino)
February 2025
Department of Vascular Surgery, ASST Settelaghi Universitary Teaching Hospital, University of Insubria, Varese, Italy.
Optimizing the longevity of vascular access in hemodialysis patients remains a critical aspect of patient care, given the significant role of arteriovenous fistulas (AVFs) and arteriovenous grafts (AVGs) in enabling effective dialysis. Vascular access complications, such as stenosis, thrombosis, and cannulation-related damage, continue to challenge both the functionality and the sustainability of these access points. Recent advancements underscore the importance of a robust follow-up strategy, integrating clinical evaluations with diagnostic tools like color Doppler ultrasound (CDU) and emerging interventional approaches such as drug-coated balloon (DCB) angioplasty.
View Article and Find Full Text PDFInt J Psychoanal
December 2024
Clinical Professor of Psychiatry, Weill Cornell Medical College, New York, USA; Editor Emeritus, The Psychoanalytic Quarterly.
Drawing upon Dana Birksted-Breen's work on temporality, and the contrast which she draws between linear, developmental time, seen as a series of unchanging moments, and bidirectional, process time, which is retranscribed again and again (Birksted-Breen [2003] 2016. "Time and the Apres-Coup." In , edited by D.
View Article and Find Full Text PDFKnee
December 2024
Orthopedic Surgery and Traumatology, Hospital Clínic de Barcelona, Barcelona, Spain.
Distal femoral replacement (DFR) with megaprostheses is a salvage revision total knee arthroplasty (rTKA) procedure indicated in cases with massive bone defects in the distal femur. As long as these implants achieve fixation only in the diaphysis, the high aseptic loosening rate reported in some series is probably related to a lack of rotational stability. Two patients with extensive distal femoral bone defects with preservation of the metaphyseal-diaphyseal junction underwent rTKA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!