A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Contactless and Simultaneous Measurement of Water and Acid Contaminations in Oil Using a Flexible Microstrip Sensor. | LitMetric

Contactless and Simultaneous Measurement of Water and Acid Contaminations in Oil Using a Flexible Microstrip Sensor.

ACS Sens

State Key Laboratory of Precision Measuring Technology & Instruments, School of Precision Instruments and Optoelectronics Engineering , Tianjin University, Tianjin 300072 , China.

Published: January 2020

The assessment of the petroleum product quality often involves multiple indicators, among which water content and acid value are two major parameters. The complexity of an oil sample and the narrow space in pipeline transport make it difficult to monitor the oil quality in real-time. Considering the practical requirements, a new type of flexible microstrip sensor is proposed in this work. The shape and line width of the microstrip sensor are studied and optimized by theory and experiments. The proposed square spiral-based microstrip sensor has good water content detection resolution at high frequencies with less acid interference, and it can determine the acid value in the low-frequency band. The sensor surface is further passivated, protecting it from direct contact with the oil sample to enhance the electrochemical robustness, and still achieves good detection linearity and high sensitivity. After encapsulation on a flexible substrate, the proposed microstrip sensor realized the non-contact determination of the water content and acid value of oil at the same time, which is only a few millimeters in size and can conform to various tubing wall shapes. Due to the fact that the manufacture of the sensor is CMOS-compatible, we expect it to be readily applied to many other miniaturized chemical-sensing applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.9b01965DOI Listing

Publication Analysis

Top Keywords

microstrip sensor
20
water content
12
flexible microstrip
8
content acid
8
oil sample
8
sensor
7
acid
5
oil
5
microstrip
5
contactless simultaneous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!