The Scanning tunneling microscope (STM) is a micro instrument designed for surface morphology with nanometer precision. The restoration of the STM image defects usually needs human judgements and manual positioning because of the diversity of the morphology and the randomness of the defects. This paper provides a new fully-automatic method that combines deep convolutional neural classification network and unique restoration algorithms corresponding to different defects. Aimed at automatically processing compound defects in STM images, the method first predicts what kinds of defects a raw STM image has by a series of parallel binary classification networks, and then decides the process order according to the predicted labels, and finally restores the defects by corresponding global restoration algorithms in order. Experiment results prove the provided method can restore the STM images by self-judging, self-positioning, self-processing without any manual intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.micron.2019.102798DOI Listing

Publication Analysis

Top Keywords

stm images
12
restoration stm
8
stm image
8
restoration algorithms
8
stm
6
defects
6
fully-automatic defects
4
defects classification
4
restoration
4
classification restoration
4

Similar Publications

We introduce a novel control mode for Scanning Tunneling Microscope (STM) that leverages di/dz feedback. By superimposing a high-frequency sinusoidal modulation on the control signal, we extract the amplitude of the resulting tunneling current to obtain a di/dz measurement as the tip is scanned over the surface. A feedback control loop is then closed to maintain a constant di/dz, enhancing the sensitivity of the tip to subtle surface variations throughout a scan.

View Article and Find Full Text PDF

The appearance of frontier molecular ion resonances measured with scanning tunneling microscopy (STM)─often referred to as orbital density images─of single molecules was investigated using a CO-functionalized tip in dependence on bias voltage and tip-sample distance. As model systems, we studied pentacene and naphthalocyanine on bilayer NaCl on Cu(111). Absolute tip-sample distances were determined by means of atomic force microscopy (AFM).

View Article and Find Full Text PDF

Chiral Nanostructures from Artificial Helical Polymers: Recent Advances in Synthesis, Regulation, and Functions.

ACS Nano

January 2025

School of Science and Engineering, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Guangdong 518172, P.R. China.

Helical structures such as right-handed double helix for DNA and left-handed α-helix for proteins in biological systems are inherently chiral. Importantly, chirality at the nanoscopic level plays a vital role in their macroscopic chiral functionalities. In order to mimic the structures and functions of natural chiral nanoarchitectures, a variety of chiral nanostructures obtained from artificial helical polymers are prepared, which can be directly observed by atomic force microscopy (AFM), scanning tunneling microscopy (STM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM).

View Article and Find Full Text PDF

Background: Acquiring new knowledge necessitates alterations at the synaptic level within the brain. Glutamate, a pivotal neurotransmitter, plays a critical role in these processes, particularly in learning and memory formation. Although previous research has explored glutamate's involvement in cognitive functions, a comprehensive understanding of its real-time dynamics remains elusive during memory tasks.

View Article and Find Full Text PDF

Electroisomerization blinking of an azobenzene derivative molecule.

Nanotechnology

January 2025

University Lille, CNRS, University Polytechnique Hauts-de-France, UMR 8520-IEMN-Institut d'Electronique de Microélectronique et de Nanotechnologie, F-59000 Lille, France.

We report here the reversibility and bistability of the switching behavior in an azobenzene derivative induced by the bias applied by a scanning-tunneling microscopy (STM) tip, at low temperature and in ultra-high vacuum environment. Thisto-andto-switching were observed during STM imaging in either polarity at +2 V or -2 V, on a sub-second time scale. This results in a blinking effect visible on STM images, corresponding to the reversible switching of the azobenzene molecule under the applied STM bias through an electric field induced process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!