Interventional magnetic resonance imaging (MRI) procedures promise to open-up new vistas regarding clinically relevant diagnostic and/or therapeutic procedures in the field of cardiology. However, a number of major limitations and challenges regarding interventional cardiovascular magnetic resonance (CMR) procedures still delay their translation from pre-clinical studies to human application. A CMR-conditional cardiac phantom was constructed using MR-safe or -conditional materials only that is based on a unique modular composition allowing quick replacement of individual components. A maximal flow of 76 ml/sec in the aorta and 111 ml/sec in the pulmonary artery were measured, whereas the maximal flow velocity was 56 cm/sec and 89 cm/sec, respectively. A conventional wedge-pressure catheter was advanced over a MRI-conditional guidewire into the right ventricle and thereafter positioned in the pulmonary artery. Pulmonary artery pressure was measured, obtaining the following values for our cardiac phantom: max/min/mean = 16/10/12 mmHg. The presented CMR-conditional cardiac phantom is the first of its kind that does not only mimic cardiac mechanics with adjustable fluid pressure in a four chamber setup that is closely adapted to that of the human heart, but also enables introduction and testing of interventional tools such as guidewires and catheters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6934499PMC
http://dx.doi.org/10.1038/s41598-019-56506-8DOI Listing

Publication Analysis

Top Keywords

cardiac phantom
16
cmr-conditional cardiac
12
pulmonary artery
12
cmr procedures
8
magnetic resonance
8
maximal flow
8
cardiac
6
introduction cmr-conditional
4
phantom
4
phantom simulating
4

Similar Publications

Purpose: Introducing compensated variable-prephasing (CVP), a phantom-based method for gradient waveform measurements. The technique is based on the variable-prephasing (VP) method, but takes into account the effects of all gradients involved in the measurement.

Methods: We conducted measurements of a trapezoidal test gradient and of an EPI readout gradient train with three approaches: VP, CVP, and fully compensated variable-prephasing (FCVP).

View Article and Find Full Text PDF

On the Effect of the Patient Table on Attenuation in Myocardial Perfusion Imaging SPECT.

EJNMMI Phys

January 2025

Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital (Ruhr University Bochum), Medical Faculty OWL (Bielefeld University), Bad Oeynhausen, Germany.

Background: The topic of the effect of the patient table on attenuation in myocardial perfusion imaging (MPI) SPECT is gaining new relevance due to deep learning methods. Existing studies on this effect are old, rare and only consider phantom measurements, not patient studies. This study investigates the effect of the patient table on attenuation based on the difference between reconstructions of phantom scans and polar maps of patient studies.

View Article and Find Full Text PDF

Background: Real-time (RT) phase contrast (PC) flow MRI can potentially be used to measure blood flow in arrhythmic patients. Undersampled RT PC has been combined with online compressed sensing (CS) reconstruction (CS RT) enabling clinical use. However, CS RT flow has not been validated in a clinical setting.

View Article and Find Full Text PDF

Anomalous aortic origin of coronary artery can lead to ischemia. Due to the limitations of invasive catheterization dobutamine stress testing, an alternative noninvasive approach is desired. A 65-year-old woman with atypical chest pain was referred for coronary computed tomography angiography.

View Article and Find Full Text PDF

Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .

Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!