Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Bisphenol A (BPA), a known potential endocrine disrupting compound (EDC) is expected to be present in low quantities in canned food due to its migration from the inner surface coating of cans made of epoxy resins. A selective and confirmatory analytical method, based on microwave assisted extraction (MAE), molecularly imprinted solid phase extraction (MISPE) using a polymer prepared by a non-covalent molecular imprinting technique and liquid chromatography coupled with electrospray ionization mass spectrometry (LC-ESI/MS) was developed for the determination of BPA in canned pineapple, tuna and mushrooms. First, the effect of the loading medium of hydro- organic solutions on the binding of BPA and its deuterated analogue on the MISPE sorbent was investigated. Subsequently, the effects of the experimental conditions of the microwave assisted extraction (solvent, sample mass/solvent volume, time and temperature) on the obtained recovery of BPA from canned food were assessed and the parameters were optimized to provide maximum recovery and selectivity. It was demonstrated that the combination of MAE with MISPE permits the use of a selective extraction solvent (methanol/water, 4/6, v/v), simplifying the sample preparation steps and enhancing sample clean-up of complex food matrices. The method was validated in different food matrices, using BPA-d16 as internal standard and quantitative relative recoveries were determined. The precision (RSD %) of the method ranged from 7% to 10% and the limit of detection was at low ng/g level for all food matrices. The determined concentration of BPA in commercial canned samples ranged between 7.3 and 42.3 ng/g.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2019.121938 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!