A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an Objective Portable Measurement Device for Spinal Joint Accessory Motion Testing. | LitMetric

Development of an Objective Portable Measurement Device for Spinal Joint Accessory Motion Testing.

Sensors (Basel)

Department of Physical Therapy and Assistive Technology, National Yang-Ming University, Taipei 11221, Taiwan.

Published: December 2019

Joint accessory motion testing (JAMT) is a standard procedure used by manual therapists to assess and treat musculoskeletal disorders. Joint accessory motion (JAM) is movement that occurs between joint surfaces, and can be induced by applying force. The motion amount, end feel, symptoms, and resistance perceived by therapists during test procedures are recorded as evidence for the diagnosis, prognosis, treatment decision making, and intervention outcome. However, previous studies have shown that accessory motion tests have insufficient reliability. Recently, many instruments have been developed to increase test reliability, but these instruments quantify the test results with a single probe and utilize the external environment as a reference. Therefore, the measured displacement amount may be affected by other spinal segments. This study proposes an objective portable measurement device with two indenter probes for spinal JAMT, wherein the JAM was quantified by displacement and force measurements between two bones. The instrument was verified with a homemade spinal simulator and computer simulation. The results showed that the force-displacement curves measured by the JAMT device (JAMTD) and those simulated by the computer model exhibited similar characteristics. Moreover, a two-probe measurement could distinguish the differences in stiffness better than a one-probe measurement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6983015PMC
http://dx.doi.org/10.3390/s20010100DOI Listing

Publication Analysis

Top Keywords

accessory motion
16
joint accessory
12
objective portable
8
portable measurement
8
measurement device
8
motion testing
8
reliability instruments
8
motion
5
development objective
4
measurement
4