A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Normal tolerance limits for side-to-side differences in diameters of major lower limbs arteries of 228 healthy subjects. | LitMetric

AI Article Synopsis

  • The study aimed to establish reference values and tolerance limits for the sizes of certain arteries in the lower limbs.
  • Measurements were taken from 228 healthy volunteers using ultrasound technology to assess the diameter of arteries during diastole.
  • Results showed specific diameter ranges for each artery, indicated tolerance limits for size differences between left and right sides, and highlighted that age and body weight influence vessel sizes, with minor gender differences observed in one artery.

Article Abstract

Purpose: To determine reference values and tolerance limits of between-side differences for the calibers of the common femoral artery (CFA), superficial femoral artery (SFA), popliteal artery (PA), dorsalis pedis artery (DPA), and posterior tibial artery (PTA).

Materials And Methods: Calibers of arteries, defined as the largest distance between internal hyperechogenic lines of the intima-media complex of the arterial wall, were measured during the diastole phase determined from echo-tracking B mode ultrasound scanning and grey-scale ultrasound in 228 healthy volunteers aged 18-81 years (43.1 ± 16.7).

Results: The mean, 95% confidence and tolerance limits covering 90% of population for left and right side of each artery were: CFA: 8.1 mm, 7.9-8.3 mm, 6.0-10.3 mm; 8.1 mm, 7.9-8.5 mm, 5.9-10.2 mm; SFA: 6.2 mm, 6.0-6.3 mm, 4.7-7.6 mm; 6.1 mm, 6.0-6.3 mm, 4.7-7.6 mm; PA: 6.1 mm, 6.0-6.2 mm, 4.6-7.6 mm; 6.1 mm, 5.9-6.2 mm, 4.5-7.6 mm; DPA: 2.0 mm, 1.9-2.0 mm, 1.2-2.7 mm; 2.0 mm, 1.9-2.0 mm, 1.2-2.8 mm; PTA: 2.1 mm, 2.0-2.1 mm, 1.4-2.8 mm; 2.1 mm, 2.1-2.2 mm, 1.4-2.8 mm, respectively. Tolerance limits for between-side differences and ratios were: CFA - 0.5-0.7 mm, 0.9-1.1; SFA - 0.5-0.6 mm, 0.9-1.1; PA - 0.5-0.5 mm, 0.9-1.1; DPA -0.4-0.4 mm, 0.8-1.2; PTA - 0.4-0.4 mm, 0.8-1.2. Regression analysis showed weight and age dependency of vessels diameters. There are no differences between men and woman in vessels size, except in DPA's, when body weight and age are taken into account in a regression analysis.

Conclusions: We estimated normal reference tolerance limits of side-to-side differences in diameters of lower limb arteries. The limits can inform an investigator what differences in diameters occur in healthy individuals, and hence can serve as cut-offs in diagnostic and screening strategies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.advms.2019.10.001DOI Listing

Publication Analysis

Top Keywords

tolerance limits
20
differences diameters
12
limits side-to-side
8
side-to-side differences
8
228 healthy
8
limits between-side
8
between-side differences
8
femoral artery
8
artery cfa
8
60-63 mm 47-76 mm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!