A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

FACTORS ASSOCIATED WITH THE USE OF 360-DEGREE LASER RETINOPEXY DURING PRIMARY VITRECTOMY WITH OR WITHOUT SCLERAL BUCKLE FOR RHEGMATOGENOUS RETINAL DETACHMENT AND IMPACT ON SURGICAL OUTCOMES (PRO STUDY REPORT NUMBER 4). | LitMetric

Purpose: To determine factors associated with 360-degree laser retinopexy (360LR) during primary pars plana vitrectomy ± scleral buckle for rhegmatogenous retinal detachment (RRD) and its impact on surgical outcomes.

Methods: This is a multicenter, retrospective, interventional study. Patients undergoing primary pars plana vitrectomy or primary pars plana vitrectomy + scleral buckle for noncomplex primary RRD in 2015 were evaluated. Primary outcomes were single surgery anatomical success (SSAS) and final anatomical success. Secondary outcomes included final logarithm of the minimum angle of resolution visual acuity, epiretinal membrane formation, cystoid macular edema development, and number of subsequent vitrectomies. Multivariate regressions were performed.

Results: Two thousand two hundred and forty-eight surgeries by 61 surgeons were included; of which, 516 underwent 360LR. Younger age (P = 0.01), more retinal breaks (P = 0.01), more extensive RRD (P < 0.001), and surgeon ID (P < 0.001) were significantly associated with 360LR. No significant associations between 360LR and single surgery anatomical success (P = 0.44), epiretinal membrane formation (P = 0.14), cystoid macular edema development (P = 0.28), or number of subsequent vitrectomies (P = 0.41) were found. Controlling for case complexity, 360LR was significantly associated with lower final anatomical success (P < 0.001) and worse final logarithm of the minimum angle of resolution visual acuity (P < 0.001).

Conclusion: Multiple factors influenced whether 360LR was performed during primary pars plana vitrectomy ± scleral buckle for RRD. However, 360LR was not associated with improved surgical outcomes, and in fact, it may be associated with poorer outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IAE.0000000000002728DOI Listing

Publication Analysis

Top Keywords

vitrectomy scleral
16
scleral buckle
16
primary pars
16
pars plana
16
plana vitrectomy
16
anatomical success
16
factors associated
8
associated 360-degree
8
360-degree laser
8
laser retinopexy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!