A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Delivering the diluted contrast agent with saline via a spiral flow tube improves arterial enhancement for contrast enhancement of magnetic resonance angiography of the neck: A retrospective study. | LitMetric

A contrast agent can be pushed by a saline solution more effectively through a spiral flow tube than through a conventional T-shaped tube in contrast-enhanced magnetic resonance angiography (CEMRA). To compare the degree of contrast enhancement and signal stability in the carotid artery by using CEMRA between a spiral flow tube and a T-shaped tube.A total of 100 patients were analyzed in this retrospective study. The first 50 patients underwent CEMRA of the carotid artery with the T-shaped tube, while the last 50 patients used the spiral flow tube. Gadoterate meglumine was diluted with saline to make a total volume of 20 mL. Injection was performed with a bolus rate of 2.5 mL/s for 8 seconds. Five regions of interest (ROIs) were placed on the contrast-enhanced area in each carotid artery and the signal intensity (SI) in the ROI was used for the analysis. The ROIs on the brain stem were also placed and the average SI in this ROI was used as a reference signal. The enhancement of the artery (Eartery) was calculated as a normalized signal using the following equation: Eartery = SI in the ROI of the carotid bifurcation/SI in the ROI of the brain stem. Signal homogeneity in the contrast-enhanced area (SHenhance) was assessed by calculating the coefficient of variation from the SI in the 5 ROIs. The value of SHenhance and Eartery between the data obtained from the spiral flow tube and the T-shaped tube were compared. P-values <.05 were considered significant.We found a significant difference in SHenhance between the data obtained from the spiral flow tube (0.20 ± 0.060) and the T-shaped tube (0.24 ± 0.056) (P = .001). The Eartery values significantly increased by 15% (spiral flow tube, median 14.1 with interquartile range [IQR] 11.8-15.4 vs T-shaped tube, median 12.3 IQR 11.3-14.0, P = .02) using the spiral flow tube.These findings suggest that, by using the Spiral flow tube, the homogeneity of the contrast-enhanced signal intensity in the carotid artery was significantly improved without decreasing the signal intensity in CEMRA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6946492PMC
http://dx.doi.org/10.1097/MD.0000000000018526DOI Listing

Publication Analysis

Top Keywords

spiral flow
20
flow tube
20
t-shaped tube
12
carotid artery
12
contrast agent
8
tube
8
contrast enhancement
8
magnetic resonance
8
resonance angiography
8
retrospective study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!