A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A rapid and non-invasive fluorescence method for quantifying coenzyme Q10 in blood and urine in clinical analysis. | LitMetric

A rapid and non-invasive fluorescence method for quantifying coenzyme Q10 in blood and urine in clinical analysis.

J Clin Lab Anal

Laboratory of Alzheimer's Optoelectric Therapy, Alzheimer's disease Center, Beijing Institute of Brain Disorders, Center for Brain Disorders Research, Capital Medical University, Beijing, China.

Published: April 2020

Background: Coenzyme Q10 (CoQ10) supplementation can improve cognition in patients with Alzheimer's disease (AD) and AD transgenic model mice. To ameliorate the discomfort that patients with AD suffer after several blood extractions, a non-invasive method for detecting urine CoQ10 levels needs to be established.

Methods: Here, we developed a new technique of fluorescence spectrophotometry with ethyl cyanoacetate (FS-ECA), on the basis of the principle that the chemical derivative obtained from the interaction between CoQ10 and ECA was detected by a fluorescence detector at λ  = 450/515 nm. As a standard reference method, the same batches of the clinical samples were analyzed by high-performance liquid chromatography with an ultraviolet detector (HPLC-UV) at 275 nm.

Results: The limits of detection (LOD) and limits of quantization (LOQ) (serum: 0.021 and 0.043 mg/L; urine: 0.012 and 0.025 mg/L) determined by the FS-ECA method were similar to that obtained through HPLC-UV (serum: 0.017 and 0.035 mg/L; urine: 0.012 and 0.025 mg/L). More importantly, this new FS-ECA technique as well as the conventional HPLC-UV method could detect a marked difference in urine CoQ10 levels between AD and controls.

Conclusion: Our findings suggest that this non-invasive method for quantifying urine CoQ10 potentially replaces HPLC to detect blood CoQ10.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7171321PMC
http://dx.doi.org/10.1002/jcla.23130DOI Listing

Publication Analysis

Top Keywords

urine coq10
12
method quantifying
8
coenzyme q10
8
non-invasive method
8
coq10 levels
8
urine 0012
8
0012 0025 mg/l
8
method
6
urine
6
coq10
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!