A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In Vitro Evaluation of the Effect of Different Surface Treatments of a Hybrid Ceramic on the Microtensile Bond Strength to a Luting Resin Cement. | LitMetric

The aim of the present study was to investigate the effect of different surface treatments of a hybrid ceramic, Vita Enamic, on the micro-tensile bond strength (µ-TBS) to resin cement. Ten blocks (3×10×8 mm) were retrieved from the original blocks and divided into 5 groups according to the different surface treatments performed: Groups 1: 35% acid phosphoric for 60 seconds (PA); group 2: Sandblasting with 50 µm Al O particles for 10 seconds (SB); groups 3: 9.5% hydrofluoric acid for 60 seconds (HF), group 4: The Er:YAG laser (2 W, 10 Hz) (ER1), group 5: The Er:YAG laser (3 W, 10 Hz) (ER2). All treated surfaces were salinized and the blocks with similar surface treatments were bonded together using a dual-cured resin cement and light-cured. After 24-hour storage in water, the blocks were cut into beams (1 mm). Half of the specimens in each group (n=16) were tested immediately and the rest were subjected to thermocycling between 5°C and 55°C for 6000 cycles before the µ-TBS test at a crosshead speed of 0.5 mm/min. The data were analyzed using two-way analysis of variance (ANOVA) and Tukey HSD tests and the significance level was set at 0.05. The failure mode was evaluated by using a stereomicroscope. The µ-TBS was clearly influenced by surface treatment methods ( < 0.001) and thermocycling significantly decreased the bond strength values in all groups ( = 0.007). The highest value (66.07 MPa ± 11.3) was obtained for the HF groups with no thermocycling and the lowest values were observed in the laser groups with no significant difference among different irradiation parameters. Adhesive failure was mainly observed in the PA and SB groups while mixed failure was predominantly shown in the laser and HF groups. This study demonstrated that surface treatment of VE with HF and salinization could improve the bond strength to a dual-cured resin cement, and Er:YAG laser irradiation with the evaluated parameters did not promote the adhesion of the resin cement to VE.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6885908PMC
http://dx.doi.org/10.15171/jlms.2019.48DOI Listing

Publication Analysis

Top Keywords

resin cement
20
surface treatments
16
bond strength
16
eryag laser
12
treatments hybrid
8
hybrid ceramic
8
groups
8
seconds group
8
group eryag
8
dual-cured resin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!