Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Transseptal puncture (TSP) is widely used in catheter-based cardiac procedures to gain left atrial access, but its workflow has remained largely unchanged in the last 50 years. This study evaluated the safety and efficacy of a novel, simplified technique for TSP with a radiofrequency (RF)-powered guidewire that eliminates multiple exchanges required with standard needles.
Methods: TSP was performed in 84 patients undergoing left-sided procedures (72 atrial fibrillation ablations [32 RF, 40 cryoballoon], 4 atrial tachycardia ablations, 2 ventricular arrhythmia ablations, 6 left atrial appendage closure) utilizing a stiff, exchange length RF guidewire. Under fluoroscopic and echocardiographic guidance, the RF guidewire was used to facilitate septal puncture with RF energy and provide a rail for advancing catheters to the left atrium without exchange. All procedures were performed under general anesthesia or sedation.
Results: TSP was achieved in all patients with no complications. The RF guidewire allowed catheters to be tracked back up to the superior vena cava without exchange in cases where another dropdown was desired to locate a preferred puncture site. The stiffness of the wire provided adequate support to advance all sheaths to the left side regardless of outer diameter.
Conclusion: TSP was performed safely and successfully for various left heart procedures with a RF guidewire that served as an RF transseptal device and a stiff guidewire. This allowed for a more efficient and potentially safer technique without the need for re-wiring or an over the wire sheath exchange. This provides substantial savings in both time and materials.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10840-019-00615-x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!