Statement Of Problem: Digital scans should be able to accurately reproduce the different complex geometries of the patient's mouth. Mesh quality of the digitized mouth is an important factor that influences the capabilities of the geometry reproduction of an intraoral scanner (IOS). However, the mesh quality capabilities of IOSs and the relationship with different ambient light scanning conditions are unclear.

Purpose: The purpose of this in vitro study was to measure the impact of various light conditions on the mesh quality of different IOSs.

Material And Methods: Three IOSs were evaluated-iTero Element, CEREC Omnicam, and TRIOS 3-with 4 lighting conditions-chair light, 10 000 lux; room light, 1003 lux; natural light, 500 lux; and no light, 0 lux. Ten digital scans per group were made of a mandibular typodont. The mesh quality of digital scans was analyzed by using the iso2mesh MATLAB package. Two-way ANOVA and Kruskal-Wallis 1-way ANOVA statistical tests were used to analyze the data (á=.05).

Results: Significant differences in mesh quality values were found among the different IOSs under the same lighting conditions and among the different lighting conditions using the same IOS. TRIOS 3 showed the highest consistency and mesh quality mean values across all scanning lighting conditions tested. CEREC Omnicam had the lowest mean mesh quality values across all scanning lighting conditions. iTero Element displayed some consistency in the mesh quality values depending on the scanning lighting conditions: chair light and room light conditions presented good consistency in mesh quality, indicating better mesh quality, and natural light and no light conditions displayed differing consistency in mesh quality values. Nevertheless, no light condition led to the minimal mean mesh quality across all IOS groups.

Conclusions: Differences in the mesh quality between different IOSs should be expected. The photographic scanning techniques evaluated presented higher mesh quality mean values than the video-based scanning technology tested. Moreover, changes in lighting condition significantly affect mesh quality. TRIOS 3 showed the highest consistency in terms of the mean mesh quality, indicating better photographic system in comparison with iTero Element.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2019.06.004DOI Listing

Publication Analysis

Top Keywords

mesh quality
68
quality values
24
lighting conditions
20
mesh
17
quality
17
digital scans
16
light conditions
16
consistency mesh
16
light
12
scanning lighting
12

Similar Publications

Study Question: How accurately can artificial intelligence (AI) models predict sperm retrieval in non-obstructive azoospermia (NOA) patients undergoing micro-testicular sperm extraction (m-TESE) surgery?

Summary Answer: AI predictive models hold significant promise in predicting successful sperm retrieval in NOA patients undergoing m-TESE, although limitations regarding variability of study designs, small sample sizes, and a lack of validation studies restrict the overall generalizability of studies in this area.

What Is Known Already: Previous studies have explored various predictors of successful sperm retrieval in m-TESE, including clinical and hormonal factors. However, no consistent predictive model has yet been established.

View Article and Find Full Text PDF

Robotic Resection of an Ectopic Parathyroid Gland: A Systematic Review.

Cureus

December 2024

General Surgery, East Sussex Healthcare NHS Trust, Brighton and Hove, GBR.

Ectopic parathyroid glands result from abnormal migration during development. If not detected promptly, they can lead to persistent or recurrent primary hyperparathyroidism (pHPT). Inferior parathyroid glands are typically located in the anterior mediastinum, while superior parathyroid glands are often near the tracheoesophageal groove, both of which contribute to pHPT.

View Article and Find Full Text PDF

Background: In order to increase the stability of tibial component in total knee arthroplasty (TKA), intramedullary stem extensions (SE) have been developed. The aim of this systematic review and meta-analysis is to address the critical knowledge gap on post-operative outcomes and complications rate comparison between tibial component with SE compared to the tibial component standard configuration (SC) in primary cemented TKA.

Methods: We conducted a comprehensive search of online databases, including Pubmed, Embase, ISI Web of science, Cochrane Library, and Scopus, using the following MeSH terms, (total knee arthroplasty) OR (TKA) OR (total knee replacement) AND (Tibial stem) OR (stem extension) OR (long stem).

View Article and Find Full Text PDF

A hybrid microgrid powered by hydrogen is an energy infrastructure that depends on hydrogen as its primary energy carrier within a localized network. This study proposed a novel bi-level optimization approach to enhance power quality and cost efficiency of the system. In the quest to improve energy management systems (EMS) and enhance power quality, a bi-level optimization approach named Particle swarm optimization-Modified water wave optimization (PSO-MWWO) has been proposed.

View Article and Find Full Text PDF

The eye is considered to be an immune-privileged region. However, several parts of the eye have distinct mechanisms for delivering immune cells to the injury sites or even in response to aging. Although these immune responses are intended to be protective, the visual acuity can be compromised by the release of pro-inflammatory cytokines by immune cells, which induce chronic inflammation and fibrosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!