While various electronic components based on carbon nanotubes (CNTs) have already been demonstrated, the realization of miniature electromagnetic coils based on CNTs remains a challenge. Coils made of single-wall CNTs with accessible ends for contacting have been recently demonstrated but were found unsuitable to act as electromagnetic coils because of electrical shorting between their turns. Coils made of a few-wall CNT could in principle allow an insulated flow of current and thus be potential candidates for realizing CNT-based electromagnetic coils. However, no such CNT structure has been produced so far. Here, we demonstrate the formation of few-wall CNT coils and characterize their structural, optical, vibrational, and electrical properties using experimental and computational tools. The coils are made of CNTs with 2, 3, or 4 walls. They have accessible ends for electrical contacts and low defect densities. The coil diameters are on the order of one micron, like those of single-wall CNT coils, despite the higher rigidity of few-wall CNTs. Coils with as many as 163 turns were found, with their turns organized in a rippled raft configuration. These coils are promising candidates for a variety of miniature devices based on electromagnetic coils, such as electromagnets, inductors, transformers, and motors. Being chirally and enantiomerically pure few-wall CNT bundles, they are also ideal for fundamental studies of interwall coupling and superconductivity in CNTs.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.nanolett.9b03977DOI Listing

Publication Analysis

Top Keywords

electromagnetic coils
16
coils
12
few-wall cnt
12
accessible ends
8
cnt coils
8
cnts
6
few-wall
5
cnt
5
few-wall carbon
4
carbon nanotube
4

Similar Publications

Background: Low-field open magnetic resonance imaging (MRI) systems, typically operating at magnetic field strengths below 1 Tesla, has greatly expanded the accessibility of MRI technology to meet a wide range of patient needs. However, the inherent challenges of low-field MRI, such as limited signal-to-noise ratios and limited availability of dedicated radiofrequency (RF) coils, have prompted the need for innovative coil designs that can improve imaging quality and diagnostic capabilities. In this work, we introduce a multimodal axial array resonator and its implementation in a volume coil, or referred to as a coupled stack-up volume coil, to address these challenges in low-field open MRI.

View Article and Find Full Text PDF

In transcranial magnetic stimulation (TMS), pulsed magnetic fields are applied to the brain, typically requiring high-power stimulators with high voltages and low series impedance. TMS pulse generators for small animal coils, are underexplored, with limited dedicated circuits and simulation models. Here, we present a new design for a high-power TMS pulse generator for small animals, utilizing a pre-charged supercapacitor that is sufficient to produce repeated pulses for TMS applications without the need for recharging.

View Article and Find Full Text PDF

Tracking head movement inside an MR scanner using electromagnetic coils.

Heliyon

July 2024

Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK.

Prospective motion corrections in brain imaging for MRI are fairly challenging. Monitoring involuntary head movement inside MR scanner is crucial for prospective motion correction. This initial study delves into utilizing simulations to track the head's movements within an MRI scanner, achieved by measuring induced voltage changes from time-varying magnetic field gradients in head-mounted coils.

View Article and Find Full Text PDF

Fluorine-19 (F) MRI has become an established tool for in vivo cell tracking following ex vivo or in vivo labelling of various cell types with F perfluorocarbons (PFCs). Here, we developed and evaluated novel mouse-specific radiofrequency (RF) hardware for improved dual H anatomical imaging and deep tissue F MR detection of PFCs. Three linearly polarized birdcage RF coils were constructed-a dual-frequency H/F coil, and a pair of single-frequency H and F coils, designed to be used sequentially.

View Article and Find Full Text PDF

Holistic numerical simulation of a quenching process on a real-size multifilamentary superconducting coil.

Nat Commun

December 2024

Q-MAT | Experimental Physics of Nanostructured Materials (EPNM), Department of Physics, University of Liege (ULiege), B5a, 4000, Liège, Belgium.

Superconductors play a crucial role in the advancement of high-field electromagnets. Unfortunately, their performance can be compromised by thermomagnetic instabilities, wherein the interplay of rapid magnetic and slow heat diffusion can result in catastrophic flux jumps, eventually leading to irreversible damage. This issue has long plagued high-J NbSn wires at the core of high-field magnets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!