Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
To monitor rodent colony health in research facilities, soiled-bedding sentinel (SBS) animals have traditionally been used. SBS can be tested by various methods, which may include serology, PCR analysis, and necropsy. Several pathogens are unreliably detected by using SBS or transmitted poorly through soiled bedding, and collection and evaluation of SBS samples can be time-intensive. Recently, exhaust air dust (EAD) testing through PCR analysis has emerged as an adjunct or replacement method for rodent colony health monitoring. EAD monitoring may provide a more efficient, sensitive, and humane method for monitoring health status. Using both EAD and SBS health monitoring, we evaluated colony health over the course of 1 y in 3 research barrier rooms in which mice were housed exclusively on IVC racks. Three pathogens- spp., spp. (previously ), and murine norovirus (MNV)-were not excluded in 2 of the rooms, and we expected that these mice would test positive with some regularity. EAD monitoring was significantly more sensitive than SBS for detection of the bacterial agents. SBS failed to detect spp. at time points when EAD had 100% detection in the rooms that did not exclude the bacteria. The detection of MNV did not differ between health monitoring systems at any time point. The findings suggest that EAD is especially valuable in detecting bacteria poorly transmitted through soiled bedding. In addition, the corresponding results with MNV detection suggest that EAD surveillance can reliably be implemented as an alternative to SBS monitoring in a facility in which mice are housed exclusively on IVC racks.