Layer Contour Verification in Additive Manufacturing by Means of Commercial Flatbed Scanners.

Sensors (Basel)

Department of Construction and Manufacturing Engineering, University of Oviedo, c/Pedro Puig Adam, E.D.O.5, 33203 Gijon, Asturias, Spain.

Published: December 2019

Industrial adoption of additive manufacturing (AM) processes demands improvement in the geometrical accuracy of manufactured parts. One key achievement would be to ensure that manufactured layer contours match the correspondent theoretical profiles, which would require integration of on-machine measurement devices capable of digitizing individual layers. Flatbed scanners should be considered as serious candidates, since they can achieve high scanning speeds at low prices. Nevertheless, image deformation phenomena reduce their suitability as two-dimensional verification devices. In this work, the possibilities of using flatbed scanners for AM contour verification are investigated. Image distortion errors are characterized and discussed and special attention is paid to the effect caused by contact imaging sensor (CIS) scanners. To compensate this phenomena, a new local distortion adjustment (LDA) method is proposed and its distortion correction capabilities are evaluated upon actual layer contours manufactured on a fused filament fabrication (FFF) machine. This proposed method is also compared to conventional global distortion adjustment (GDA). Results reveal quasi-systematic deformations of the images which could be minimized by means of distortion correction. Nevertheless, the irregular nature of such a distortion and the superposition of different errors penalize the use of GDA, to the point that it should not be used with CIS scanners. Conclusions indicate that LDA-based correction would enable the use of flatbed scanners in AM for on-machine verification tasks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6982839PMC
http://dx.doi.org/10.3390/s20010001DOI Listing

Publication Analysis

Top Keywords

flatbed scanners
16
contour verification
8
additive manufacturing
8
layer contours
8
cis scanners
8
distortion adjustment
8
distortion correction
8
scanners
6
distortion
6
layer contour
4

Similar Publications

Real-World Implementation of Particle-Based Microfluidics: On-Spot Test for Iron and Copper Ions in Water.

ACS Omega

January 2025

Chair of Analytical Chemistry, Institute of Chemistry, University of Tartu, Ravila 14a, 50411Tartu, Estonia.

Water is an essential part of everyday life, and similarly, numerous industries depend on it. Regular water analysis is needed for both home use and in more specific fields, e.g.

View Article and Find Full Text PDF

The emergence of new technologies focusing on "computer vision" has contributed significantly to the assessment of fruit quality. In this study, an innovative approach based on image analysis was used to assess the external quality of fresh and frozen 'Mejhoul' and 'Boufeggous' date palm cultivars stored for 6 months at -10 °C and -18 °C. Their quality was evaluated, in a non-destructive manner, based on texture features extracted from images acquired using a digital camera and flatbed scanner.

View Article and Find Full Text PDF

Systematic characterization of new EBT4 radiochromic films in clinical x-ray beams.

Biomed Phys Eng Express

November 2024

Department of Advanced Radiation Oncology and Proton Therapy, Inova Schar Cancer Institute, VA, United States of America.

. We aim to characterize kinetics of radiation-induced optical density in newly released EBT4 radiochromic films exposed to clinical x-rays. Several film models and batches were evaluated for the film sensitivity, optical signal increasing with time, relative film noise, and minimum detectable limits (MDL).

View Article and Find Full Text PDF

Drought stress significantly reduces crop yields at all stages of plant development. Barley, known for its abiotic-stress adaptation among cereals was used to examine the genetic basis of drought tolerance. A population of 164 spring barley lines was subjected to polyethylene glycol (PEG) induced drought stress during germination and seedling development.

View Article and Find Full Text PDF

Purpose: Radiochromic EBT3 films are commonly used as dosimeter for clinical practice and research on radiotherapy. In principle, they are associated with a flatbed scanner to determine the optical density change, which can be correlated to the absorbed dose after calibration. Several approaches have been proposed to reduce the uncertainties during acquisition and to compensate the lighting inhomogeneities, thus improving the dose measurement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!