Aims: Patients referred to the cath-lab are an increasingly elderly population. Thermodilution (TD, gold standard) and the estimated Fick method (eFM) are interchangeably used in the clinical routine to measure cardiac output (CO). However, their correlation in an elderly cohort of cardiac patients has not been tested so far.

Methods: A single, clinically-indicated right heart catheterization was performed on each patient with CO estimated by eFM and TD in 155 consecutive patients (75.1±6.8 years, 57.7% male) between April 2015 and August 2017. Whole Body Oxygen Consumption (VO2) was assumed by applying the formulas of LaFarge (LaF), Dehmer (De) and Bergstra (Be). CO was indexed to body surface area (Cardiac Index, CI).

Results: CI-TD showed an overall moderate correlation to CI-eFM as assessed by LaF, De or Be (r2 = 0.53, r2 = 0.54, r2 = 0.57, all p < .001, respectively) with large limits of agreement (-0.64 to 1.09, -1.07 to 0.77, -1.38 to 0.53 l/m2/min, respectively). The mean difference of CI between methods was 0.22, -0.15 and -0.42 (all p<0.001 for difference to TD), respectively. A rate of error ≥20% occurred with the equations by LaF, De or Be in 40.6%, 26.5% and 36.1% of patients, respectively. A CI <2.2 l/m2min was present in 42.6% of patients according to TD and in 60.0%, 31.0% and in 16.1% of patients according to eFM by the formulas of LaF, De or Be.

Conclusion: Although CI-eFM shows an overall reasonable correlation with CI-TD, the predictive value in a single patient is low. CI-eFM cannot replace CI-TD in elderly patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6924680PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0226561PLOS

Publication Analysis

Top Keywords

estimated fick
8
cardiac output
8
elderly cohort
8
thermodilution estimated
4
cardiac
4
fick cardiac
4
output measurement
4
measurement elderly
4
patients
4
cohort patients
4

Similar Publications

K2 performance depends on different kinematic and kinetic variables. Due to the lack of related studies in this area, we have tried to explain these features to better understand the best positioning of paddlers and how their synchronization affects performance. This study uses the DAQ system comprising two instrumented paddles-an IMU and a GPS ("E-kayak" system)-to investigate paddle synchronization and the specific positioning of paddlers' in preferred and inverted configurations.

View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to assess the relationship between flow measurements from left ventricular assist devices (LVADs) and invasive cardiac output measurements using different methods.
  • Researchers analyzed data from 102 LVAD patients, identifying significant discordance between methods, where 45% had differences when using indirect Fick and 48% with thermodilution compared to pump flow.
  • The findings suggested that while LVAD flow estimates correlate strongly with traditional cardiac output measures, particularly thermodilution, the correlation improves when low indirect Fick values are excluded.
View Article and Find Full Text PDF

Introduction: Cardiac intensive care providers require a comprehensive understanding of cardiac output and oxygen delivery. The estimation of cardiac output in clinical practice often relies on thermodilution and the Fick principle. Central venous saturation and lactate levels are commonly used indicators for cardiac output assessment.

View Article and Find Full Text PDF

Simulating the Permeation of Toxic Chemicals through Barrier Materials.

Membranes (Basel)

August 2024

Department of Chemical and Biological Engineering, University of Ottawa, Ottawa, ON K1N 6N5, Canada.

Chemical warfare agents that are liquids with low vapor pressure pose a contact hazard to anyone who encounters them. Personal protective equipment (PPE) is utilized to ensure safe interaction with these agents. A commonly used method to characterize the permeability of PPE towards chemical weapons is to apply droplets of the liquid agent to the surface of the material and measure for chemical breakthrough.

View Article and Find Full Text PDF

Purpose: To propose a new method for quantitatively mapping the renal metabolic rate of oxygen (RMRO) and to evaluate the proposed method using a caffeine challenge.

Theory And Methods: Pseudo-continuous arterial spin labeling (pCASL) and QSM sequences were used to obtain MR images in the kidney. Six healthy volunteers were scanned on caffeine and control days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!