Background: Data on left ventricular (LV) deformation imaging using CT angiography (CTA) are scarce and the feasibility of atrial deformation analysis by CT has not been addressed. We aimed to compare 2D echocardiographic and CT derived LV and left atrial (LA) global longitudinal strain (GLS) obtained by using a novel feature tracking algorithm in patients following transcatheter aortic valve implantation.

Methods: Twenty-eight patients were included who underwent retrospectively-gated 256-slice CTA and speckle-tracking echocardiography (STE) on the same day. CT datasets in 10% increments were reconstructed throughout the cardiac cycle. LV GLS and LA global peak reservoir strain (LA GS) was measured.

Results: Median absolute values for LV GLS were 19.9 [14.8-22.4] vs. 19.9 [16.8-24.7], as measured by CT vs STE, respectively (p = 0.017). We found good inter-modality correlation for LV GLS (ρ = 0.78, p < 0.05) with a mean bias of -1.6. Regarding atrial measurements, the median LA GS was 19.0 [13.5-27.3] for CT vs. 28.0 [17.5-32.6] for STE (p < 0.001) with a mean bias of -5.6 between CT and STE and a correlation coefficient of ρ = 0.87, p < 0.001. CT measurements were highly reproducible: intra-observer intra-class correlation coefficient was 0.96 for LV GLS and 0.95 for LA GS.

Conclusion: We detected good correlation between CTA and echocardiography-based LV and LA longitudinal strain parameters. CTA provides accurate strain measurements with high reproducibility. Feature tracking-based deformation analysis could provide a clinically important addition to CT examinations by complementing anatomical information with functional data.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcct.2019.12.004DOI Listing

Publication Analysis

Top Keywords

left ventricular
8
ventricular atrial
4
atrial strain
4
strain imaging
4
imaging cardiac
4
cardiac computed
4
computed tomography
4
tomography validation
4
validation echocardiography
4
echocardiography background
4

Similar Publications

Importance: Hypertension underpins significant global morbidity and mortality. Early lifestyle intervention and treatment are effective in reducing adverse outcomes. Artificial intelligence-enhanced electrocardiography (AI-ECG) has been shown to identify a broad spectrum of subclinical disease and may be useful for predicting incident hypertension.

View Article and Find Full Text PDF

Systolic Blood Pressure and Pulse Pressure in Heart Failure: Pooled Participant-Level Analysis of 4 Trials.

J Am Coll Cardiol

November 2024

Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA. Electronic address:

Background: Hypertension is common in patients with heart failure with mildly reduced or preserved ejection fraction (HFmrEF/HFpEF), and current guidelines recommend treating systolic blood pressure (SBP) to a target <130 mm Hg. However, data supporting treatment to this target are limited. Additionally, pulse pressure (PP), a marker of aortic stiffness, has been associated with increased risk of cardiovascular events, but its prognostic impact in HFpEF has not been extensively studied.

View Article and Find Full Text PDF

Cardiac MRI Evaluation of Determinants and Prognostic Implications of Right Ventricular Dysfunction in Aortic Regurgitation.

Radiol Cardiothorac Imaging

February 2025

From the Department of Cardiology, Houston Methodist DeBakey Heart & Vascular Center, 6550 Fannin St, Smith Tower, Ste 1801, Houston, TX 77030 (M.M., P.B., V.C., M.S., M.R., S.F.N., W.A.Z., D.J.S.); and Department of Pathology and Genomic Medicine, Houston Methodist Hospital Research Institute, Houston, Tex (D.T.N., E.A.G.).

Purpose To investigate the determinants and effect of right ventricular (RV) dysfunction in aortic regurgitation (AR) using cardiac MRI. Materials and Methods This study included patients with moderate or severe AR who were enrolled in the DEBAKEY-CMR registry between January 2009 and June 2020. Patients with previous valve intervention, cardiomyopathy deemed unrelated to AR, severe aortic stenosis, and other confounders were excluded.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.

View Article and Find Full Text PDF

Introduction: Moderate to severe tricuspid regurgitation (TR) in the setting of acute heart failure (AHF) has been found to be associated with worse clinical outcomes. Recently, the TRI-SCORE was developed to predict clinical outcomes after isolated tricuspid surgery.

Objectives: To determine whether this score could aid in risk stratification of AHF patients with moderate-severe TR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!