A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Elimination of late endoleak after endovascular repair of a dissecting thoracoabdominal aortic aneurysm]. | LitMetric

Described herein is a clinical case report regarding treatment of a 70-year-old male patient presenting with a late complication following endoprosthetic repair for a Stanford type B dissecting thoracic aortic aneurysm. The man was admitted to our hospital for persistent type IIb endoleak and an increased diameter of the aorta in its thoracic and thoracoabdominal portions. Two years previously, he had endured endoprosthetic repair of the thoracic aorta. The findings of computed tomography revealed negative dynamics manifesting as an increase in the diameter of the false channel of the arch and descending thoracic aorta with persistent type IIb endoleak. He was subjected to elimination of abdominal aortic dissection and type IIb endoleak with partial prosthetic repair of the descending thoracic portion of the aorta by means of prosthetic repair of the lower thoracic portion of the aorta between the stent graft and linear vascular Dacron prosthesis. The postoperative period was complicated by transient acute renal failure and paraparesis of the lower limbs. The patient was discharged on POD 14, with no endoleaks revealed on control computed tomography 3 months thereafter.

Download full-text PDF

Source
http://dx.doi.org/10.33529/ANGIO2019413DOI Listing

Publication Analysis

Top Keywords

type iib
12
iib endoleak
12
endoprosthetic repair
8
persistent type
8
thoracic aorta
8
computed tomography
8
descending thoracic
8
prosthetic repair
8
thoracic portion
8
portion aorta
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!