Comparing different bar materials for mandibular implant-supported overdenture: Finite-element analysis.

Indian J Dent Res

Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt; Department of Oral Technology, University of Bonn, Bonn, Germany.

Published: December 2019

Aim: This study was conducted aiming to optimize the selection of bar material that can minimize stresses on mandibular bone.

Subjects And Methods: One finite-element model was created under ANSYS environment to evaluate the use of different materials as a bar-manufacturing material in mandibular implant-supported overdenture (OD). Model components were created on engineering computer-aided design software and then assembled under the finite-element package. A force of 200 N was unilaterally and vertically applied on the left second premolar area.

Results: Within these study conditions, the polyether ether ketone bar produced the lowest Von Mises stress on OD and the maximum value of deformation. Stainless steel bar produced the maximum OD total deformation.

Conclusions: Cortical and spongy bones are not sensitive to the bar material. Increasing bar material stiffness increases Von Mises stresses in the bar itself and reduces its total deformation, in what is called overconstrained system.

Download full-text PDF

Source
http://dx.doi.org/10.4103/0970-9290.273442DOI Listing

Publication Analysis

Top Keywords

bar material
12
mandibular implant-supported
8
implant-supported overdenture
8
bar produced
8
von mises
8
bar
6
comparing bar
4
bar materials
4
materials mandibular
4
overdenture finite-element
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!