A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental and numerical investigation of a polypropylene orthotic device for assistance in level ground walking. | LitMetric

This study investigates the use of an orthotic device for improving pathologic gait lacking a heel-strike and its effect on the joint loads. The orthosis is fabricated from 10-mm thick polypropylene sheets joined together using a bolted joint. The gait trials are recorded using a Qualisys motion capture system and Kistler's force platform. The data recorded in this study comprise five male and five female participants, executing level ground gait under barefoot, shod and orthotic conditions. Computed tomography reconstructed foot bone-tissue model and computer-aided design model of the orthosis are used to predict the mechanical behaviour with and without orthosis under static loading. A one-way analysis of variance is conducted to compare the peak gait parameters in the early and late stance phase between the three walking conditions. The experimental results show that the orthosis reduces the peak joint forces and the rate of change of moment at the hip, knee and ankle joints. The finite element analysis results present a decrease in foot plantar pressure from 0.74 to 0.32 MPa with orthotic usage. The results of this study indicate that the orthosis can eliminate the heel-ground gap while retaining sufficient ankle motion and providing peak joint force reduction.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411919894091DOI Listing

Publication Analysis

Top Keywords

orthotic device
8
level ground
8
peak joint
8
orthosis
5
experimental numerical
4
numerical investigation
4
investigation polypropylene
4
orthotic
4
polypropylene orthotic
4
device assistance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!