Objective: To investigate the efficacy and safety of spinopelvic reconstruction based on a novel suspended, modular, and 3D-printed total sacral implant after total piecemeal resection of a sacral giant cell tumor (SGCT) with the preservation of bilateral S nerve roots via a posterior-only approach.

Methods: Five patients who had undergone total piecemeal resection of SGCT involving upper sacral segments (S and S ) and the midline with the preservation of bilateral S nerve roots via a posterior-only approach between September 2017 and July 2018 were retrospectively reviewed. A novel suspended, modular, and 3D-printed total sacral implant had been used for reconstruction. This series included two female and three male patients, with a mean age of 42.2 years (range, 31-53 years). Surgical time, blood loss, complications, preoperative and postoperative neurological function, instrumentation failure, and local control were presented and analyzed.

Results: All patients underwent the operation without death or serious complications. The implant was installed on the defect, connecting the ilium and lumbar vertebrae, and fixed with a screw-rod system up to the level of L or L . The mean operative time was 502 min (range, 360-640 min) and the mean operative blood loss 4400 mL (range, 3000-7000 mL). The mean follow-up was 15 months. After the operation, pain was significantly relieved, and the patients resumed walking as early as 2 weeks later. The patients showed no neurogenic bladder dysfunction and no fecal incontinence or gait disturbance. Wound healing was poor in one patient. Patients recovered well without evidence of local recurrence. No implant failures or related clinical symptoms were detected during follow up. Satisfactory bone ingrowth and osseointegration at the bone-implant junctions was found in follow-up CT.

Conclusion: Although technically challenging, it is feasible and safe to use a suspended, modular, and 3D-printed implant for reconstruction after total piecemeal resection with the preservation of bilateral S nerve roots in patients with SGCT. We believe that this implant can be applied to sacral reconstruction in a wide variety of diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7031587PMC
http://dx.doi.org/10.1111/os.12582DOI Listing

Publication Analysis

Top Keywords

suspended modular
16
modular 3d-printed
16
preservation bilateral
16
bilateral nerve
16
nerve roots
16
novel suspended
12
3d-printed total
12
total sacral
12
sacral implant
12
roots posterior-only
12

Similar Publications

Biopharmaceuticals are the fastest-growing class of drugs in the healthcare industry, but their global reach is severely limited by their propensity for rapid aggregation. Currently, surfactant excipients such as polysorbates and poloxamers are used to prevent protein aggregation, which significantly extends shelf-life. Unfortunately, these excipients are themselves unstable, oxidizing rapidly into 100s of distinct compounds, some of which cause severe adverse events in patients.

View Article and Find Full Text PDF

Using mechanical force to induce chemical reactions with two-dimensional (2D) materials provides an approach for both understanding mechanochemical processes on the molecular level, and a potential method for using mechanical strain as a means of directing the functionalization of 2D materials. To investigate this, we have designed a modular experimental platform which allows for monitoring of reactions on strained graphene Raman spectroscopy as a function of time. Both the strain present in graphene and the corresponding chemical changes it undergoes in the presence of a reagent can be followed concomitantly.

View Article and Find Full Text PDF

Microplastic sampling strategies for aquatic systems commonly employ small mesh nets to collect suspended microparticles. These methods work well for marine sampling campaigns; however, complex water systems such as freshwater rivers, effluent discharges, and stormwater ponds characterized by high total suspended solids and fast-moving water can cause the nets to clog, rip, or tear. Published in 2020, ASTM D8332 is an alternative approach to sampling complex water systems for microplastics involving pumping large volumes of water across a cascading stack of sieves to collect suspended particles.

View Article and Find Full Text PDF

Hemodialysis Wastewater Treatment via Electrocoagulation and Electro-Oxidation: Modular Pilot-Level Modeling and Simulation.

Chempluschem

June 2024

Centro de Investigación y Desarrollo Tecnológico en Electroquímica, S.C., CIDETEQ, Parque Tecnológico Querétaro, s/n, San Fandila, 76703, Pedro Escobedo, Qro., México.

Hemodialysis treatment in specialized clinics within the same hospital significantly impacts environmental water health due to contaminated wastewater. The issues observed included changes in electrical conductivity, the presence of dangerous bacterial loads, toxicity from heavy metals, total cyanide content, and helminth parasite eggs. The level of damage is dependent on the patient's health under treatment.

View Article and Find Full Text PDF

Water monitoring faces challenges that are driven by the infrastructure, protection, financial resources, science and innovation policies, among others. A modular, low-cost, fully open-source and small-sized Unmanned Surface Vessel (USV) called EMAC-USV (EMAC: Estación de Monitoreo Ambiental Costero), is proposed for monitoring bathymetry and water quality parameters (i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!