Objectives: To describe and compare a novel technique using a torque device to manage figure-of-eight suture tension for venous access hemostasis in patients who have undergone atrial septal defect (ASD) or patent foramen ovale (PFO) closure.
Background: Large bore venous access has become increasingly important in transcatheter procedures, but management of hemostasis can be time-consuming and/or resource intensive. As such, various techniques have sought to provide cost effective and safe alternatives to manual compression. We describe a modification of the figure-of-eight suture technique wherein we apply a torque device to manage variable suture tension instead of tying a knot and compare it to the standard figure-of-eight suture technique.
Methods: We performed a retrospective study of 40 consecutive patients who underwent ASD or PFO closure, 20 of whom underwent standard figure-of-eight technique and 20 of whom underwent figure-of-eight with torque device modification. Bleeding Academic Research Consortium definitions were used to categorize bleeding events.
Results: The groups were similar in age, gender, weight, aspirin use, platelet count, procedure time, hemoglobin, and international normalized ratio. Standard figure-of-eight suture had seven patients with bleeding, with six classified as BARC II and one as BARC I. Figure-of-eight plus torque device had three patients with bleeding, with two classified BARC II and one as BARC I. There were no incidences of hematoma in either group.
Conclusion: The torque device suture technique is a unique modification of the figure-of-eight suture technique to achieve venous hemostasis. In addition, the modification allows secure and variable suture tension as well as easy removal by nursing staff.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7078947 | PMC |
http://dx.doi.org/10.1002/ccd.28657 | DOI Listing |
PLoS One
January 2025
Aesthetic and Restorative Dentistry Department, College of Dentistry, University of Baghdad, Baghdad, Iraq.
This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.
View Article and Find Full Text PDFKorean J Orthod
January 2025
State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
Objective: Miniscrews are commonly utilized as temporary anchorage devices (TADs) in cases of maxillary protrusion and premolar extraction. This study aimed to investigate the effects and potential side effects of two conventional miniscrew configurations on the maxillary incisors.
Methods: Eighty-two adult patients with maxillary dentoalveolar protrusion who had undergone bilateral first premolar extraction were retrospectively divided into three groups: non-TAD, two posterior miniscrews only (P-TADs), and two anterior and two posterior miniscrews combined (AP-TADs).
Zhongguo Gu Shang
January 2025
Ningbo Beilun People's Hospital, Ningbo 315800, Zhejiang, China.
Objective: To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.
Methods: Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group.
Sci Robot
January 2025
Research Center for Information and Communication Technologies, Department of Computer Engineering, Automation and Robotics, University of Granada, Granada, Spain.
Robots have to adjust their motor behavior to changing environments and variable task requirements to successfully operate in the real world and physically interact with humans. Thus, robotics strives to enable a broad spectrum of adjustable motor behavior, aiming to mimic the human ability to function in unstructured scenarios. In humans, motor behavior arises from the integrative action of the central nervous system and body biomechanics; motion must be understood from a neuromechanics perspective.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada.
Lower-limb exoskeletons have demonstrated great potential for gait rehabilitation in individuals with motor impairments; however, maintaining human-exoskeleton coordination remains a challenge. The coordination problem, referred to as any mismatch or asynchrony between the user's intended trajectories and exoskeleton desired trajectories, leads to sub-optimal gait performance, particularly for individuals with residual motor ability. Here, we investigate the virtual energy regulator (VER)'s ability to generate coordinated locomotion in lower limb exoskeleton.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!