Background: To report current worldwide variation in techniques and clinical practice of flexible ureteroscopy (FURS) among endourologists of different case volumes per year.

Methods: Two invitations to complete an internet survey were emailed to Endourological Society members. Some of survey questions asked about indications of using FURS for renal and upper ureteral stones. Others were concerned with clinical practice of FURS (such as preoperative stenting, use of ureteral access sheath (UAS) and safety guidewire, technique of Laser lithotripsy and fragment retrieval, and post-FURS stenting. Responders were distributed into two groups; high-volume (> 100 cases/year) and low-volume surgeons (< 100 cases/year) and data were compared between both groups.

Results: Responses were received from 146 endourologists all over the world (62 high-volume and 84 low-volume). FURS for intrarenal stone > 20 mm was used by 61% of high-volume surgeons compared with 28.6% for low-volume (P < 0.001). Semirigid URS was used for upper ureteric stones in 68% among high-volume group and 82% in low-volume group (P = 0.044). UAS was used by 62% in low-volume group and 69% in high volume group (P = 0.516). Laser stone dusting was preferred by 63% in low-volume group versus 45% by high-volume (P = 0.031). More responders in low-volume group preferred to leave the stent for 6 weeks (P = 0.042).

Conclusions: The use of FURS for treating upper tract calculi has expanded by high volume endourologists to include large renal stones > 20 mm. Low-volume surgeons prefer to use semi-rigid URS for treatment of upper ureteral stones, to apply Laser stone dusting and maintain ureteral stents for longer periods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6921597PMC
http://dx.doi.org/10.1186/s12894-019-0568-zDOI Listing

Publication Analysis

Top Keywords

flexible ureteroscopy
8
clinical practice
8
upper ureteral
8
ureteral stones
8
low-volume surgeons
8
impact case
4
case volume
4
volume year
4
year flexible
4
ureteroscopy practice
4

Similar Publications

Background: Managing lower pole renal stones presents clinical challenges influenced by various factors such as stone size, location, and density. This study aims to assess the efficacy, safety, and stone-free rates of Flexible Ureteroscopy (FURS), Extracorporeal Shock Wave Lithotripsy (ESWL), and Mini Percutaneous Nephrolithotomy (Mini PCNL) for treating lower pole renal hard stones (< 2 cm).

Methods: A prospective single-centre comparative study was conducted on 414 adult patients with primary lower pole renal hard stones.

View Article and Find Full Text PDF

To assess the accuracy of Kidney Stone Calculator(KSC), a software designed for surgical planning, in predicting the duration of lithotripsy during flexible ureteroscopy(FURS) when using the novel pulsed-Thulium: YAG(p-Tm: YAG) laser. From February to August 2023, a single-center prospective study was conducted, including patients with kidney or ureteral stones through non-contrast computed tomography(NCCT), who underwent FURS with p-Tm: YAG laser lithotripsy. KSC used three-dimensional segmentation of the stones from NCCT images, along with an interactive user interface for laser settings, to estimate the stone volume(SV) and the lithotripsy duration(LD).

View Article and Find Full Text PDF

Purpose: Use of suction in flexible ureteroscopy is increasing lately. The introduction of flexible and navigable suction access sheath (FANS) has shown improved stone free rate (SFR). However, its efficacy in lower pole stone (LPS) in terms of SFR and complications is yet to be studied.

View Article and Find Full Text PDF

Novel pressure- and temperature-controlled flexible ureteroscope system with a suction ureteral access sheath: a multicenter retrospective feasibility study.

World J Urol

December 2024

Department of Urology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, No. 33 Yingfeng Road, Haizhu District, Guangzhou, 510000, Guangdong, China.

Purpose: The purpose of this study was to assess the feasibility of a pressure-controlled and temperature-controlled flexible ureteroscope system (PT Scope™) during flexible ureteroscopy.

Materials And Methods: We developed the PT Scope™, a novel ureteroscope system with capabilities for monitoring and controlling intrarenal pressure and temperature to maintain them within set parameters. Data were retrospectively collected from 48 consecutive patients diagnosed with upper urinary tract stones who underwent flexible ureteroscopic lithotripsy using the PT Scope™ across five centers in China.

View Article and Find Full Text PDF

Background: Flexible ureteroscopy (FURS) is increasingly used as the first-line treatment for urological procedures. Disposable digital (dd-)FURS has been developed to overcome limitations such as durability, degradation, and repair cost of reusable scopes. The diameter of commercially-available models ranges from 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!