Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To analyze the effectiveness and stability of the refractive, topographic and visual outcomes of the standard cross-linking (SCXL) in keratoconus (KC) management.
Patients And Methods: This study was designed as a retrospective non-comparative study that included 28 KC patients (n=49 eyes) who performed SCXL as a single procedure to treat KC and completed five-year follow-up period. The topographic, refractive and visual data were recorded preoperatively and at 12, 24, 36 and 60 months postoperatively.
Results: Forty eyes (81.6%) showed achieved postoperative spherical equivalent (SE) refraction better than the attempted refraction. Ten eyes (20.4%) improved by <1 D, 23 eyes (46.9%) improved from 1 D to <2 D and 7 eyes (14.3%) improved by ≥2 D. Both uncorrected distant visual acuity (UDVA) and corrected distant visual acuity (CDVA) showed statistically significant improvement from preoperative 1.34±0.29 (mean±SD) and 0.74±0.23 LogMAR to postoperative 0.99±0.32 and 0.50±0.22 LogMAR (P<0.0001) respectively. Both Kmax and SE refraction showed statistically significant and stable improvement from preoperative 51.95±1.90 and -7.90±3.14 D to postoperative 50.19±1.96 and -6.35±2.49 D (P<0.0001) respectively. Two eyes (4%) showed KC progression at the end of 5th follow-up year.
Conclusion: SCXL had good effectiveness and stability that halted KC progression over 5-year follow-up period. It had also unexpected improvement in the KC refractive components mainly the spherical and SE components.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6913285 | PMC |
http://dx.doi.org/10.2147/OPTH.S232954 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!