Selective capturing of phenolic derivative by a binary metal oxide microcubes for its detection.

Sci Rep

Department of Chemistry, King Abdulaziz University, Jeddah, 21589, P.O. Box 80203, Saudi Arabia.

Published: December 2019

Development of highly efficient and potential material for toxic p-nitrophenol is an important design for sensitive detection of hazardous species from ecology and environment. Here it is developed, an efficient as well as selective of p-nitrophenol using binary material by electrochemical performances, including good linearity, lower detection limit, good stability, higher reproducibility and extreme sensitivity. The prepared electrode was fabricated by immobilization of SnO/CdO microcubes (MCs) with conducting coating binders by using well-known glassy carbon electrode (GCE). The proposed MCs with SnO/CdO were well-functionalized and prepared by facile hydrothermal technique. The general instrumentation namely, FTIR, UV/vis, FESEM, XPS, TEM, EDS, and powder XRD were employed for the morphological evaluation of the prepared doped MCs, structural, optical and elemental analyses. The large dynamic range (LDR) from 1.0 to 0.01 mM with 0.13 pM detection limit (S/N = 3), limit of quantification (LOQ; 0.43 pM), and an excellent sensitivity of 7.12 µAµMcm were exhibited by the fabricated binary material based on SnO/CdO MCs for selective p-nitrophenol capturing. In shortly, the SnO/CdO MCs can be employed as an efficient electron mediator with binary materials fabricated GCE for capturing the p-nitrophenol at ultra-trace amounts. Then the binary synthesized material of SnO/CdO MCs is used as potential and sensitive sensor layer by stable electrochemical approach for sensitive capturing of toxic p-nitrophenol from environmental samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6917752PMC
http://dx.doi.org/10.1038/s41598-019-55891-4DOI Listing

Publication Analysis

Top Keywords

sno/cdo mcs
12
toxic p-nitrophenol
8
selective p-nitrophenol
8
binary material
8
detection limit
8
mcs
6
binary
5
p-nitrophenol
5
sno/cdo
5
selective capturing
4

Similar Publications

Selective capturing of phenolic derivative by a binary metal oxide microcubes for its detection.

Sci Rep

December 2019

Department of Chemistry, King Abdulaziz University, Jeddah, 21589, P.O. Box 80203, Saudi Arabia.

Development of highly efficient and potential material for toxic p-nitrophenol is an important design for sensitive detection of hazardous species from ecology and environment. Here it is developed, an efficient as well as selective of p-nitrophenol using binary material by electrochemical performances, including good linearity, lower detection limit, good stability, higher reproducibility and extreme sensitivity. The prepared electrode was fabricated by immobilization of SnO/CdO microcubes (MCs) with conducting coating binders by using well-known glassy carbon electrode (GCE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!