A volumetric microsampling (VAMS) device (20 μl) was evaluated and validated for the analysis of γ-hydroxybutyric acid (GHB) in venous blood using a simple ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. GHB was extracted from VAMS device by acetonitrile, after a re-hydration step in a temperature-controlled ultrasonic bath at 60°C for 10 min. Chromatographic analysis was carried out on a Kinetex C column using 0.1% formic acid in water and acetonitrile as binary gradient mobile phase (from 5 to 95% of acetonitrile from 1 to 2.5 min) at a flow rate of 0.3 ml/min. The VAMS method was fully validated according to current guidelines with satisfactory results in terms of linearity, selectivity, precision, absolute recovery, matrix effect and stability. The linearity was determined from 0.5 to 200 μg/ml and the lower limit of quantitation was 0.5 μg/ml. The novel VAMS-UHPLC-MS/MS method was successfully compared with plasma-based method in a GHB-treated patient as a proof of concept.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.4781DOI Listing

Publication Analysis

Top Keywords

vams device
8
development validation
4
validation volumetric
4
volumetric absorptive
4
absorptive microsampling
4
microsampling coupled
4
coupled uhplc-ms/ms
4
uhplc-ms/ms analysis
4
analysis gamma-hydroxybutyric
4
gamma-hydroxybutyric acid
4

Similar Publications

Development and validation of a quantification method for direct oral anticoagulants from capillary blood using volumetric absorptive microsampling and online SPE-LC-MS.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, University of Muenster, Muenster, Germany. Electronic address:

The number of prescriptions for new direct oral anticoagulants (DOACs) apixaban, edoxaban, rivaroxaban and dabigatran has increased exponentially in recent years, increasingly replacing the old gold standard, vitamin-K-antagonists. Due to their wide therapeutic range, therapeutic drug monitoring (TDM) is not required, although it has been proven that this could significantly reduce side effects. In order to develop a cost-efficient and simple method for the simultaneous detection of the DOACs and phenprocoumon, a new technology for sample preparation from capillary blood in the ambulant sector named VAMS® was integrated and an LC-MS detector with on-line solid phase extraction (SPE) applying a Turboflow HTLC Cyclone 1.

View Article and Find Full Text PDF

Volumetric absorptive microsampling meets electromembrane extraction for the first time: Case example of doxorubicin and its metabolite in whole blood samples.

Anal Chim Acta

January 2025

Department of Pharmaceutical Chemistry and Pharmaceutical Analysis, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 03, Hradec Králové, Czech Republic. Electronic address:

Background: Microsampling of biological fluids followed by innovative sample pre-treatment reflects trends in bioanalytical chemistry. Volumetric absorptive microsampling (VAMS) enables exact whole blood volume collection and reduces the impact of hematocrit on the assay. In animal studies, it complies with the 3R principles (refine, reduce, replace).

View Article and Find Full Text PDF

Quantitative analysis of cannabinoids and metabolites in oral fluid by volumetric absorptive microsampling combined with UHPLC-HRMS.

Anal Bioanal Chem

December 2024

Laboratoire de Toxicologie, Fédération de Toxicologie, Hôpital Lariboisière AP-HP, 2 Rue Ambroise Paré, 75010, Paris, France.

Article Synopsis
  • The increasing legalization of cannabis worldwide has led to a growing need for methods to accurately identify and quantify cannabis consumption, especially through non-invasive means.
  • Oral fluid, as an alternative to traditional blood and urine tests, offers advantages such as easier self-sampling and reduced risk of tampering, although it typically requires larger volumes to test effectively.
  • The study presents a new method that allows for the quantification of seven cannabinoids from just 20 µL of oral fluid using a specialized sampling device and advanced chemical techniques, achieving precise detection limits suitable for legal and clinical contexts.
View Article and Find Full Text PDF

Evaluation of tolerability and safety of transcranial electrical stimulation with gel particle electrodes in healthy subjects.

Front Psychiatry

November 2024

Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China.

Background: With the advancement of transcranial electrical stimulation (tES) technology, an increasing number of stimulation devices and treatment protocols have emerged. However, safety and tolerability remain critical concerns before new strategies can be implemented. Particularly, the use of gel particle electrodes brings new challenges to the safety and tolerability of tES, which hinders its widespread adoption and further research.

View Article and Find Full Text PDF

Background: The benefits of pharmacotherapy with sirolimus (SIR) in pediatric transplant recipients are well established. Traditionally, whole blood samples have been used to measure SIR concentrations. Volumetric Absorptive Microsampling (VAMS) is an alternative sampling strategy suitable for Therapeutic Drug Monitoring (TDM).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!