Background And Aims: Intraoperative perforation is a major adverse event of endoscopic submucosal dissection (ESD). To avoid perforation, it is important for the endoscope to approach the portion to be resected carefully and to ensure that the knife can approach the submucosa at an angle parallel to the muscle layer. The multibending endoscope has 2 bends at its tip and may facilitate the ESD procedure. To the best of our knowledge, very few studies have reported the use of the multibending endoscope during gastric ESD. The aim of this study was, therefore, to introduce the usefulness of the multibending endoscope for gastric ESD.
Methods: We report 2 cases of early gastric cancer in which ESD was performed using a multibending endoscope.
Results: Unlike conventional single-bending endoscopes that have only 1 moveable part, the multibending endoscope allowed difficult areas to be approached more easily. Small adjustments could be made to the upward or downward angle of both the first and the second bending sections of the endoscope. This ensured that the knife would approach the submucosa at an angle parallel to the muscle layer. In patient 1, initially the conventional endoscope was used, but it became more difficult to approach the site, and paradoxic movement occurred. When the conventional endoscope was changed to the multibending endoscope, the ESD procedure became safer and more efficient. Another ESD using the multibending endoscope was performed successfully without any adverse events.
Conclusions: The use of a multibending endoscope for ESD will enable safer and faster treatment of patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6895728 | PMC |
http://dx.doi.org/10.1016/j.vgie.2019.08.012 | DOI Listing |
A 10-year-old girl was admitted to our hospital due to acute pancreatitis. Computed tomography showed an intra-gastric mass containing multiple small air bubbles. Ultrasound showed a well-circumscribed large oval mass with a broad acoustic shadow.
View Article and Find Full Text PDFGut Liver
March 2024
Department of Internal Medicine, Soonchunhyang University School of Medicine, Cheonan, Korea.
Background/aims: : Peroral cholangioscopy (POC) has been used to assess intrahepatic duct (IHD) lesions but with a limited role. A new multibending (MB) ultraslim endoscope has been designed to improve POC performance. We evaluated the usefulness of POC using the MB ultraslim endoscope for the management of IHD lesions.
View Article and Find Full Text PDFVideoGIE
February 2024
Institute of Digestive Disease, Faculty of Medicine, Chinese University of Hong Kong, Hong Kong, China.
Video 1Summary of the presented case. Macroscopic images of the lesion in a white-light endoscopy and narrow-band imaging and in an underwater view followed by scenes from the resection with circular marking, submucosal injection, circumferential incision, and submucosal dissection using a multi-bend double-channel endoscope, as well as clip traction, controlled full-thickness dissection, and inspection of the defect plus closure of the defect with the clip-and-loop technique.
View Article and Find Full Text PDFEndoscopy
December 2023
Center for Gastroenterology, Teine Keijinkai Hospital, Hokkaido, Japan.
Endoscopy
December 2023
Department of Gastrointestinal Oncology, Osaka International Cancer Institute, Osaka, Japan.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!