We report the case of a 45-year old female patient with a past medical history of rheumatoid arthritis who presented to our cardiology department with a suspicion of inappropriate sinus tachycardia. Echocardiography showed a nondilated left ventricle with a preserved ejection fraction. A careful reinterpretation of her 12-lead ECG reoriented the diagnosis toward an incessant atrial tachycardia. The diagnosis was confirmed by an electrophysiologic study performed with an electro-anatomic mapping system, which identified the origin of the tachycardia at the level of the right atrial appendage. Radiofrequency ablation of the ectopic focus eliminated the tachycardia and improved the patient's symptoms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6898534PMC
http://dx.doi.org/10.1002/joa3.12250DOI Listing

Publication Analysis

Top Keywords

inappropriate sinus
8
sinus tachycardia
8
tachycardia
5
tachycardia or…something
4
or…something else?
4
else? report
4
report case
4
case 45-year
4
45-year female
4
female patient
4

Similar Publications

Background: Supraventricular tachycardia (SVT) is very common in daily clinical practice, especially in the emergency department, with rapid onset and urgent management. The review highlights the recent genetic predispositions and mechanisms in SVT.

Methods: Through analysis of epidemiology, familial clustering, and gene mutations of the relevant literature,the review elucidates the genetic properties and potential pathophysiology of SVT.

View Article and Find Full Text PDF

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Background: Left bundle branch block (LBBB) is a rare conduction disorder in athletes associated with ventricular dyssynchrony, which can lead to left ventricular systolic dysfunction and exercise intolerance. Inappropriate sinus tachycardia (IST) is characterized by an excessive heart rate (HR) that is not related to physiological needs, often resulting in reduced exercise capacity. Managing these conditions in athletes can be challenging, as standard treatments like beta-blockers and ivabradine, while effective in controlling HR, are described to be associated with a reduction in maximal exercise performance.

View Article and Find Full Text PDF

Inappropriate sinus tachycardia (IST) presents challenges in diagnosis and treatment due to its unclear etiology and limited therapeutic options. This case report explores the use of continuous stellate ganglion block (CSGB) as a potential treatment avenue. A 23-year-old woman with refractory IST underwent several CSGB placements, resulting in prolonged symptom relief and decreased median heart rate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!