A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Left ventricular pacing in patients with preexisting tricuspid valve disease. | LitMetric

Background: Conventional right ventricular (RV) pacing is increasingly recognised to cause tricuspid valve (TV) injury or dysfunction, in part due to the need to pass the lead through the valve. This may be especially problematic in patients with preexisting TV disease or prior TV surgery. An alternative in this situation is to implant a left ventricular (LV) lead instead of ventricular pacing.

Methods: We performed a single-center retrospective analysis of 26 patients with tricuspid valve surgery/disease who received a LV pacing lead in the coronary veins to avoid crossing the tricuspid valve, with or without a right atrial lead. A matched control population was obtained from patients receiving conventional right ventricular pacing and outcomes were compared. Main outcomes of interest were lead stability, electrical lead parameters and change in echocardiographic parameters such as left ventricular ejection fraction (LVEF) during long-term follow-up.

Results: Successful left ventricular pacing was established in 25 out of the 26 cases with one case converted to a RV lead due to lead dislodgement. During the 2.96 ± 1.0 year follow-up, 24 of 25 (96.0%) leads were functional with stable pacing and sensing parameters, and 1 of 25 (4.0%) was extracted for due to device infection following an episode of thrombophlebitis.

Conclusion: We conclude that in patients with existing tricuspid valve disease or surgery, ventricular pacing via the coronary veins is a feasible, safe, and reliable alternative to right ventricular pacing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6898538PMC
http://dx.doi.org/10.1002/joa3.12257DOI Listing

Publication Analysis

Top Keywords

ventricular pacing
24
tricuspid valve
20
left ventricular
16
pacing
8
patients preexisting
8
valve disease
8
ventricular
8
conventional ventricular
8
lead
8
coronary veins
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!