Objective: The clinical benefit of ursodeoxycholic acid (UDCA) in primary biliary cholangitis (PBC) has never been reported in absolute measures. The aim of this study was to assess the number needed to treat (NNT) with UDCA to prevent liver transplantation (LT) or death among patients with PBC.

Methods: The NNT was calculated based on the untreated LT-free survival and HR of UDCA with respect to LT or death as derived from inverse probability of treatment weighting-adjusted Cox proportional hazard analyses within the Global PBC Study Group database.

Results: We included 3902 patients with a median follow-up of 7.8 (4.1-12.1) years. The overall HR of UDCA was 0.46 (95% CI 0.40 to 0.52) and the 5-year LT-free survival without UDCA was 81% (95% CI 79 to 82). The NNT to prevent one LT or death within 5 years (NNT) was 11 (95% CI 9 to 13). Although the HR of UDCA was similar for patients with and without cirrhosis (0.33 vs 0.31), the NNT was 4 (95% CI 3 to 5) and 20 (95% CI 14 to 34), respectively. Among patients with low alkaline phosphatase (ALP) (≤2× the upper limit of normal (ULN)), intermediate ALP (2-4× ULN) and high ALP (>4× ULN), the NNT to prevent one LT or death was 26 (95% CI 15 to 70), 11 (95% CI 8 to 17) and 5 (95% CI 4 to 8), respectively.

Conclusion: The absolute clinical efficacy of UDCA with respect to LT or death varied with baseline prognostic characteristics, but was high throughout. These findings strongly emphasise the incentive to promptly initiate UDCA treatment in all patients with PBC and may improve patient compliance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7398464PMC
http://dx.doi.org/10.1136/gutjnl-2019-319057DOI Listing

Publication Analysis

Top Keywords

95% 95%
12
number needed
8
needed treat
8
ursodeoxycholic acid
8
prevent liver
8
liver transplantation
8
transplantation death
8
primary biliary
8
biliary cholangitis
8
udca
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!