A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interpretation Accuracy and Interrater Agreement of Pediatric Skin and Soft Tissue Point-of-Care Ultrasound Images among Residents and Faculty. | LitMetric

Background: Point-of-care ultrasound (POCUS) is commonly used to facilitate care in the emergency department. Acquired images are often reviewed by local experts for educational and quality assurance purposes. However, no published study has examined the accuracy and reliability of POCUS image interpretation by multiple reviewers.

Objectives: We studied the accuracy and interrater agreement among expert and trainee reviewers of prerecorded pediatric skin and soft tissue (SST) POCUS images.

Methods: POCUS faculty and emergency medicine (EM) residents blindly reviewed deidentified pediatric SST POCUS images and indicated whether a drainable fluid collection was present, absent, or indeterminate. This was then compared with the gold standard based on discharge diagnoses and telephone follow-up. Images rated as indeterminate were excluded from the initial analysis. Sensitivity analysis assuming indeterminate answers were inaccurate was subsequently conducted.

Results: In phase 1, 6 pediatric EM POCUS directors reviewed 168 images. The overall accuracy was 79.7% (range 66.1-86.0%). The mean Cohen's kappa was 0.58 (range 0.24-0.84). Sensitivity analysis yielded an overall accuracy of 71.3% (range 56.5-76.9%) and a Cohen's kappa of 0.43 (range 0.20-0.59). In phase 2, 6 general EM POCUS faculty and 20 EM residents reviewed 120 images. The overall accuracy among residents was 72.2% (range 51.4-84.7%) and among faculty was 83.6% (range 77.9-88.8%). Sensitivity analysis yielded an overall resident accuracy of 63.0% (range 49.5-80.7) and an overall faculty accuracy of 73.9% (range 67.0-79.8%). Fleiss' kappa was 0.322 for residents and 0.461 for faculty.

Conclusions: We found moderate accuracy and fair to good interrater agreement among POCUS faculty and EM residents reviewing pediatric SST POCUS images.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jemermed.2019.10.028DOI Listing

Publication Analysis

Top Keywords

interrater agreement
12
sst pocus
12
pocus faculty
12
sensitivity analysis
12
pocus
9
accuracy interrater
8
pediatric skin
8
skin soft
8
soft tissue
8
point-of-care ultrasound
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!