Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Femoral neck fractures are commonly encountered clinical problems, especially in patients with osteoporosis, and have high morbidity and mortality. Internal fixation of femoral neck fractures using 3 cannulated screws placed in an inverse triangle configuration is commonly performed. Recently, the use of 4 cannulated screws in a rhombic configuration has been proposed. The aim of this study was to investigate the outcomes of femoral neck fractures treated using either an inverse triangle or rhombic configuration to determine which had a better clinical prognosis. A total of 138 consecutive patients without any previous hip surgery who had femoral neck fractures treated with cannulated compression screws in either an inverse triangle or rhombic configuration were reviewed. Patients' demographic and radiological data were collected from the authors' institutional database. The authors found that the rhombic configuration did not have a better result in decreasing complications, such as femoral neck shortening or screw exit, or in Harris Hip Scores and other clinical prognoses compared with the inverse triangle configuration. In addition, the technique used for applying 4 screws (especially the posterior ones) needs to be improved, so until then, using 3 screws in an inverse triangle configuration remains the gold standard for the treatment of femoral neck fractures. [Orthopedics. 2020; 43(2):e72-e78.].
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/01477447-20191212-03 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!