Background Tetralogy of Fallot repair results in late occurrence of pulmonary regurgitation, which requires pulmonary valve replacement in a large proportion of patients. Both homografts and bioprostheses are used for pulmonary valve replacement as uncertainty remains on which prosthesis should be considered superior. We performed a long-term imaging and clinical comparison between these 2 strategies. Methods and Results We compared echocardiographic and clinical follow-up data of 209 patients with previous tetralogy of Fallot repair who underwent pulmonary valve replacement with homograft (n=75) or bioprosthesis (n=134) between 1995 and 2018 at a tertiary hospital. The primary end point was the composite of pulmonary valve replacement reintervention and structural valve deterioration, defined as a transpulmonary pressure decrease ≥50 mm Hg or pulmonary regurgitation degree of ≥2. Mixed linear model and Cox regression model were used for comparisons. Echocardiographic follow-up duration was longer in the homograft group (8 [interquartile range, 4-12] versus 4 [interquartile range, 3-6] years; <0.001). At the latest echocardiographic follow-up, homografts showed a significantly lower transpulmonary systolic pressure decrease (16 [interquartile range, 12-25] mm Hg) when compared with bioprostheses (28 [interquartile range, 18-41] mm Hg; mixed model <0.001) and a similar degree of pulmonary regurgitation (degree 0-4) (1 [interquartile range, 0-2] versus 2 [interquartile range, 0-2]; mixed model =0.19). At 9 years, freedom from structural valve deterioration and reintervention was 81.6% (95% CI, 71.5%-91.6%) versus 43.4% (95% CI, 23.6%-63.2%) in the homograft and bioprosthesis groups, respectively (adjusted hazard ratio, 0.27; 95% CI, 0.13-0.55; <0.001). Conclusions When compared with bioprostheses, pulmonary homografts were associated lower transvalvular gradient during follow-up and were associated with a significantly lower risk of reintervention or structural valve degeneration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6951084PMC
http://dx.doi.org/10.1161/JAHA.119.013654DOI Listing

Publication Analysis

Top Keywords

pulmonary valve
20
valve replacement
20
tetralogy fallot
12
pulmonary
8
fallot repair
8
pulmonary regurgitation
8
[interquartile range
8
valve
6
replacement
5
long-term comparison
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!