Background: During spontaneous breathing trial, low-pressure support is thought to compensate for endotracheal tube resistance, but it actually should provide overassistance. Automatic tube compensation is an option available in the ventilator to compensate for flow-resistance of endotracheal tube. Its effects on patient effort have been poorly investigated. We aimed to compare the effects of low-pressure support and automatic tube compensation during spontaneous breathing trial on breathing power and lung ventilation distribution.
Results: We performed a randomized crossover study in 20 patients ready to wean. Each patient received both methods for 30 min separated by baseline ventilation: pressure support 0 cmHO and automatic tube compensation 100% in one period and pressure support 7 cmHO without automatic tube compensation in the other period, a 4 cmHO positive end-expiratory pressure being applied in each. Same ventilator brand (Evita XL, Draeger, Germany) was used. Breathing power was assessed from Campbell diagram with esophageal pressure, airway pressure, flow and volume recorded by a data logger. Lung ventilation distribution was assessed by using electrical impedance tomography (Pulmovista, Draeger, Germany). During the last 2 min of low-pressure support and automatic compensation period breathing power and lung ventilation distribution were measured on each breath. Breathing power generated by the patient's respiratory muscles was 7.2 (4.4-9.6) and 9.7 (5.7-21.9) J/min in low-pressure support and automatic tube compensation periods, respectively (P = 0.011). Lung ventilation distribution was not different between the two methods.
Conclusions: We found that ATC was associated with higher breathing power than low PS during SBT without altering the distribution of lung ventilation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6911134 | PMC |
http://dx.doi.org/10.1186/s13613-019-0611-y | DOI Listing |
Zhongguo Shi Yan Xue Ye Xue Za Zhi
December 2024
Department of Blood Transfusion, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200127, China.
Objective: To investigate and assess hemolytic transfusion reaction in patient with complex and combined anti-Fy and anti-Jk which so as to provide a safety blood transfusion strategy.
Methods: ABO/Rh blood grouping, antibody screening and identification, and Coombs' tests were performed by the routine serological methods include manual tube and automatic blood group analyzer with matching micro-column gel cards from Diagnostic Grifols and Jiangsu LIBO. The hospital information system and laboratory information system were used to collect dada on patients' blood routine tests, liver and kidney function, coagulation, cardiac function, and other clinical indicators before and after blood transfusion were analyzed and compared in conjunction with the patients' clinical manifestations.
Gen Thorac Cardiovasc Surg
December 2024
Department of General Thoracic Surgery, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chiba, 260-8670, Japan.
Background: Air leakage during pulmonary resection is a major complication in thoracic surgery. It frequently occurs at sites of adhesion dissection, due to lung manipulation, and along the staple lines of automatic suturing devices, particularly in cases of pulmonary fragility such as those of emphysema and interstitial pneumonia. Persistent postoperative air leakage prolongs chest tube indwelling and extends hospitalization time.
View Article and Find Full Text PDFBMC Med Inform Decis Mak
December 2024
Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, P. R. China.
Background: The low tube-voltage technique (e.g., 80 kV) can efficiently reduce the radiation dose and increase the contrast enhancement of vascular and parenchymal structures in abdominal CT.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
Chemical Engineering Department, ESEIAAT-UPC, Colom 11, 08222 Terrassa, Spain.
A new method is proposed to generate hydrogen in situ at low pressure from powder-pressed recycled aluminum turnings activated with small amounts of NaOH and drops of water. The contribution of this system is that the user can obtain small flows of high-purity hydrogen (>99%) to charge their portable electronic devices in remote places, in a simple, controlled, and safe way, since only water is used. Test tubes that contain tiny amounts of NaOH on their surface can be transported and used without contact.
View Article and Find Full Text PDFPhys Med
December 2024
Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden; Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden.
Purpose: To investigate the feasibility of evaluating the functionality of x-ray angiography systems based on detailed exposure data extracted from DICOM radiation dose structured reports (RDSR).
Methods: Structured reports provide information about each x-ray irradiation event (a fluoroscopy or acquisition series) part of a clinical procedure. This data was utilized to evaluate the functionality of angiography systems installed in three pediatric and adult cardiology suites, one abdominal radiology suite, and two neurology suites.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!