The opacity of conventional ultrasound transducers can impede the miniaturization and workflow of current photoacoustic systems. In particular, optical-resolution photoacoustic microscopy (OR-PAM) requires the coaxial alignment of optical illumination and acoustic-detection paths through complex beam combiners and a thick coupling medium. To overcome these hurdles, we developed a novel OR-PAM method on the basis of our recently reported transparent lithium niobate (LiNbO) ultrasound transducer (Dangi et al., Optics Letters, 2019), which was centered at 13 MHz ultrasound frequency with 60% photoacoustic bandwidth. To test the feasibility of wearable OR-PAM, optical-only raster scanning of focused light through a transducer was performed while the transducer was fixed above the imaging subject. Imaging experiments on resolution targets and carbon fibers demonstrated a lateral resolution of 8.5 µm. Further, we demonstrated vasculature mapping using chicken embryos and melanoma depth profiling using tissue phantoms. In conclusion, the proposed OR-PAM system using a low-cost transparent LiNbO window transducer has a promising future in wearable and high-throughput imaging applications, e.g., integration with conventional optical microscopy to enable a multimodal microscopy platform capable of ultrasound stimulation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6960623PMC
http://dx.doi.org/10.3390/s19245470DOI Listing

Publication Analysis

Top Keywords

optical-resolution photoacoustic
8
photoacoustic microscopy
8
ultrasound transducer
8
ultrasound
5
transducer
5
microscopy
4
microscopy transparent
4
transparent ultrasound
4
transducer opacity
4
opacity conventional
4

Similar Publications

Low-cost microvascular phantom for photoacoustic imaging using loofah.

J Biomed Opt

January 2025

Washington University in St. Louis, Department of Biomedical Engineering, St. Louis, Missouri, United States.

Significance: Existing photoacoustic phantoms are unable to mimic complex microvascular structures with varying sizes and distributions. A suitable material with structures that mimic intricate microvascular networks is needed.

Aim: Our aim is to introduce loofah as a natural phantom material with complex fiber networks ranging from 50 to , enabling the fabrication of phantoms with controlled optical properties comparable to those of human microvasculature.

View Article and Find Full Text PDF

Optical resolution photoacoustic imaging of uneven samples without z-scanning is transformative for the fast analysis and diagnosis of diseases. However, current approaches to elongate the depth of field (DOF) typically imply cumbersome postprocessing procedures, bulky optical element ensembles, or substantial excitation beam side lobes. Metasurface technology allows for the phase modulation of light and the miniaturization of imaging systems to wavelength-size thickness.

View Article and Find Full Text PDF

Resolution Enhancement Strategies in Photoacoustic Microscopy: A Comprehensive Review.

Micromachines (Basel)

November 2024

Beijing Key Laboratory for Precision Optoelectronic Measurement Instrument and Technology, School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.

Photoacoustic imaging has emerged as a promising modality for medical imaging since its introduction. Photoacoustic microscopy (PAM), which is based on the photoacoustic effect, combines the advantages of both optical and acoustic imaging modalities. PAM facilitates high-sensitivity, high-resolution, non-contact, and non-invasive imaging by employing optical absorption as its primary contrast mechanism.

View Article and Find Full Text PDF

Optical-resolution photoacoustic microscopy enables cellular-level biological imaging in deep tissues. However, acquiring high-quality spatial images without knowing the point spread function (PSF) at multiple depths or physically improving system performance is challenging. We propose an adaptive multi-layer photoacoustic image fusion (AMPIF) approach based on blind deconvolution and registration.

View Article and Find Full Text PDF

Optical-resolution parallel ultraviolet photoacoustic microscopy for slide-free histology.

Sci Adv

December 2024

Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA.

Intraoperative imaging of slide-free specimens is crucial for oncology surgeries, allowing surgeons to quickly identify tumor margins for precise surgical guidance. While high-resolution ultraviolet photoacoustic microscopy has been demonstrated for slide-free histology, the imaging speed is insufficient, due to the low laser repetition rate and the limited depth of field. To address these challenges, we present parallel ultraviolet photoacoustic microscopy (PUV-PAM) with simultaneous scanning of eight optical foci to acquire histology-like images of slide-free fresh specimens, improving the ultraviolet PAM imaging speed limited by low laser repetition rates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!