Results From a Second-Generation Vestibular Implant in Human Subjects: Diagnosis May Impact Electrical Sensitivity of Vestibular Afferents.

Otol Neurotol

Department of Otolaryngology, Virginia Merrill Bloedel Hearing Research Center, National Primate Research Center, University of Washington, Seattle, Washington.

Published: January 2020

Objective: Auditory and vestibular outcomes after placement of a vestibular-cochlear implant in subjects with varying causes of vestibular loss.

Study Design: Prospective case study.

Setting: Tertiary referral center.

Patients: Three human subjects received a vestibular-cochlear implant. Subject 1 had sudden hearing and vestibular loss 10 years before implantation. Subjects 2 and 3 had bilateral Menière's disease with resolution of acute attacks. All subjects had severe-profound deafness in the implanted ear and bilateral vestibular loss.

Intervention: Vestibular-cochlear implant with electrode positions confirmed by CT.

Main Outcome Measures: Electrically-evoked vestibular and cochlear compound action potentials (ECAPs), speech perception, and electrically-evoked slow-phase eye velocities.

Results: Subject 1 had no vestibular ECAP, but normal cochlear ECAPs and cochlear implant function. She had minimal eye-movement with vestibular stimulation. Subject 2 had vestibular ECAPs. This subject had the largest eye velocities from electrical stimulation that we have seen in humans, exceeding 100 degrees per second. Her cochlear implant functions normally. Subject 3 had vestibular and cochlear ECAPs, and robust eye-movements and cochlear implant function.

Conclusion: The etiology of vestibular loss appears to have a profound impact on sensitivity of vestibular afferents in distinction to cochlear afferents. If this dichotomy is common, it may limit the application of vestibular implants to diagnoses with preserved sensitivity of vestibular afferents. We speculate it is due to differences in topographic organization of Scarpa's versus the spiral ganglion. In two subjects, the second-generation device can produce higher velocity eye movements than seen in the four subjects receiving the first-generation device.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000002463DOI Listing

Publication Analysis

Top Keywords

vestibular
14
sensitivity vestibular
12
vestibular afferents
12
vestibular-cochlear implant
12
subject vestibular
12
cochlear implant
12
human subjects
8
vestibular loss
8
vestibular cochlear
8
cochlear ecaps
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!