A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions. | LitMetric

AI Article Synopsis

  • The GammaPod is a specialized machine designed for breast cancer treatment using stereotactic radiosurgery, featuring 25 rotating cobalt-60 sources for precise dose delivery.
  • Two patient-specific quality assurance (PSQA) methods are implemented: one based on physical measurements and the other on calculated doses using a unique software, ensuring the accuracy of radiation treatment.
  • Results revealed that the GammaPod's performance aligns closely with treatment plans, achieving a high gamma pass rate for dose distributions and confirming the system's reliability for accurate and precise dose calculations in breast cancer therapy.

Article Abstract

Purpose: The GammaPod is a dedicated prone breast stereotactic radiosurgery (SRS) machine composed of 25 cobalt-60 sources which rotate around the breast to create highly conformal dose distributions for boosts, partial-breast irradiation, or neo-adjuvant SRS. We describe the development and validation of a patient-specific quality assurance (PSQA) system for the GammaPod.

Methods: We present two PSQA methods: measurement based and calculation based PSQA. The measurements are performed with a combination of absolute and relative dose measurements. Absolute dosimetry is performed in a single point using a 0.053-cc pinpoint ionization chamber in the center of a polymethylmethacrylate (PMMA) breast phantom and a water-filled breast cup. Relative dose distributions are verified with EBT3 film in the PMMA phantom. The calculation-based method verifies point doses with a novel semi-empirical independent-calculation software.

Results: The average (± standard deviation) breast and target sizes were 1263 ± 335.3 cc and 66.9 ± 29.9 cc, respectively. All ion chamber measurements performed in water and the PMMA phantom agreed with the treatment planning system (TPS) within 2.7%, with average (max) difference of -1.3% (-1.9%) and -1.3% (-2.7%), respectively. Relative dose distributions measured by film showed an average gamma pass rate of 97.0 ± 3.2 when using a 3%/1 mm criteria. The lowest gamma analysis pass rate was 90.0%. The independent calculation software had average agreements (max) with the patient and QA plan calculation of 0.2% (2.2%) and -0.1% (2.0%), respectively.

Conclusion: We successfully implemented the first GammaPod PSQA program. These results show that the GammaPod can be used to calculate and deliver the predicted dose precisely and accurately. For routine PSQA performed prior to treatments, the independent calculation is recommended as it verifies the accuracy of the planned dose without increasing the risk of losing vacuum due to prolonged waiting times.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6909122PMC
http://dx.doi.org/10.1002/acm2.12778DOI Listing

Publication Analysis

Top Keywords

dose distributions
12
relative dose
12
development validation
8
patient-specific quality
8
quality assurance
8
measurements performed
8
pmma phantom
8
pass rate
8
independent calculation
8
breast
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!