A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of a low-stress and low-contamination clamping method for large-aperture optics. | LitMetric

Motivated by the need to decrease initial contact seal stress on Nd:glass coated with SiO sol-gel film and effectively control the surface contaminants from film debris induced by stress in the assembly process, a novel vacuum clamping method is studied to achieve the purpose of low stress and low contamination. In this article, theoretical analyses, numerical simulations, and field experiments are used to verify the feasibility of this method. Mechanical simulation results indicate that under the same radial compression conditions, the higher the hollowness of the O-ring rubber, the less the contact stress on Nd:glass. In addition, microstructures of the SiO sol-gel film are observed by scanning electron microscopy, and the damage mechanism is analyzed in order to optimize assembly stress. By optimizing the distribution of hollowness, the honeycomb structure is proved to have lower contact stress due to its larger deformation. Finally, experimental results verify that the low-stress vacuum clamping method can meet the strict surface cleanliness requirements of Nd:glass. This study also provides a promising method for clean assembly of other large-aperture optics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10358571PMC
http://dx.doi.org/10.1177/0036850419880109DOI Listing

Publication Analysis

Top Keywords

clamping method
12
large-aperture optics
8
stress ndglass
8
sio sol-gel
8
sol-gel film
8
vacuum clamping
8
contact stress
8
stress
6
method
5
investigation low-stress
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!